BENDIX/KING
5.3.4.2
Recommended Disassembly Procedures
A.
Bottom Cover Removal
1.
Turn unit over so the Bottom Cover (047-12425-0006) is facing up.
2.
Remove nine fasteners (089-06008-0003) securing the Bottom Cover to the
Top Cover (047-12426-0006).
3.
Remove two fasteners (089-06008-0004) securing the Bottom Cover to the
Front Panel assembly (200-09673-0001).
4.
Lift Bottom Cover assembly off, and swing to left side of unit.
5.
Locate and disengage ribbon cable (155-02937-0001) from P5006 on the
Main Board Assembly (200-09638-0001).
6.
The Bottom Cover is now free.
B.
Power Board Removal
1.
Perform steps outlined in step A.
Page 5-32
WARNING
REMOVE ALL POWER FROM THE UNIT BE-
FORE DISASSEMBLY OF ANY MODULE. BE-
SIDES BEING DANGEROUS TO LIFE, VOLT-
AGE TRANSIENTS CAN CAUSE CONSIDER-
ABLE DAMAGE TO THE EQUIPMENT.
CAUTION
EXERCISE EXTREME CARE WHEN DISCON-
NECTING AND RECONNECTING MULTIPLE
PIN CONNECTORS, TO ENSURE THAT THE
CONNECTORS ARE NOT DAMAGED BY MIS-
ALIGNMENT OF THE PINS.
View unit from front, with display to the top, for deter-
mining left and right sides, top and bottom. Tag, or by
some means identify, all disconnected wires or coax-
ial cables. Refer to unit and board level assembly
drawings as additional aids in assembly/disassem-
bly procedures.
CAUTION
THIS EQUIPMENT CONTAINS ELECTRO-
STATIC DISCHARGE SENSITIVE (ESDS) DE-
VICES. EQUIPMENT, MODULES, AND ESDS
DEVICES MUST BE HANDLED IN ACCOR-
DANCE WITH SPECIAL ESDS HANDLING
PROCEDURES.
15599M00.JA