Disassemble the KLN 94 to allow a small Philips-head screwdriver to access the
contrast adjustment Variable Resistor. This Variable Resistor is labeled "VR1",
and is located near the bottom center on the printed circuit card of the 043-05012-
01 LCD Color Display. Easy access will require either the removal of the KLN 94's
top cover, or an extender for the J5007 and J5009 Main Board connectors. It is not
necessary to extend J5001.
Next, plug the unit's connectors back together and re-apply power to the KLN 94.
Go to the TST 11 page and set the contrast value to 128 as outlined in Paragraph
B. Rotate VR1 until the point of best contrast is obtained (as defined in Paragraph
C). Re-assemble the KLN 94 and repeat the contrast alignment as outlined in
Paragraph A.
5.2.4
FINAL TEST PROCEDURE
If an in-service unit tests within the acceptable limits given in this test procedure, no further testing
is required and the unit shall be considered suitable for installation in an aircraft.
5.2.4.1
SYSTEM ERROR
A.
Set the TEST switch (S9) to open.
B.
Turn the unit power on.
C.
Check to verify that the following page is not displayed.
D.
If no failure is indicated, continue testing.
5.2.4.2
UNIT SOFTWARE VERSION
A.
Press the ENT button four times.
B.
Turn the right knobs until the Aux 14 page is visible.
C.
This page will display the revision of software in the unit.
D.
Record software data on the Final Data Sheet.
5.2.4.3
UNIT INITIALIZATION
A.
Turn right outer knob to set page 1.
B.
Press the CRSR button.
C.
Set the initial position to a location near to the user's present position, i.e. KIXD,
OJC.
D.
Press ENT three times to validate the choice.
E.
Turn the right inner knob to the SET 2 page.
Page 5-8
KLN94 SYSTEM ERROR
ERROR CODE XXX
15599M00.JA