Usb Connectors; E-Sata Connector (Only Divar An 5000); Alarm I/O Connections - Bosch DIVAR AN 5000 Operation Manual

Digital video recorder
Hide thumbs Also See for DIVAR AN 5000:
Table of Contents

Advertisement

DIVAR AN 3000 / DIVAR AN 5000
Figure 5.5: RS232 serial port
Signal name
DCD_in
RX
TX
N/C
System ground
N/C
RTS
CTS
N/C
5.8

USB connectors

Two USB 2.0 connectors (one on front panel, one on rear panel) can be used on the unit to
connect a mouse or USB memory device. (Recording to a USB drive is not supported.)
Figure 5.6: USB connector (on front and on rear)
Note:
USB memory sticks must have FAT32 formatting. See Technical Specifications for a list of
compatible USB memory device types that are supported.
5.9

e-SATA connector (only DIVAR AN 5000)

An e-SATA connector is located at the rear panel of the unit to connect an e-SATA device. This
can be used to expand the number of available hard disks.
e-SATA
Note:
The connected hard disks must be Bosch approved. See technical Specifications for a list of
compatible HDDs models that can be connected to the e-SATA connection.
5.10

Alarm I/O connections

Alarm inputs and outputs are fitted as screw down terminal blocks on the unit. Cable cross
section is AWG 26-16 (0.13 to 1.5 mm
Bosch Security Systems
Pin number
Description
1
Carrier detection signal (not used)
2
RS232 receive signal
3
RS232 transmit signal
4
No connection
5
System ground
6
No connection
7
RS232 request to send signal
8
RS232 clear to send signal
9
No connection
).
2
Operations Manual
Hardware setup | en
33
2015.02 | 2.1 | AM18-Q0669

Advertisement

Table of Contents
loading

Table of Contents