Changing the Blade
Standard Blades
WARNING! DISCONNECT THE
SCROLL SAW FROM THE MAINS
BEFORE CONTINUING.
1) Lift up the blade tensioning clamp lever and rotate
until the tension on the blade has been released,
see fig 7 on page 12.
2) Remove the table insert, see fig 23.
3) Remove the blade guard (B) and place safely aside,
see fig 24.
4) Beneath the table to the side of the machine there
is an access door, using a Phillips screwdriver loosen
the right hand screw and slide the door away to gain
access to the lower blade holder assembly, see fig
25-26.
5) Using a 3mm Hex Key loosen the Hex screws on
the blade holders and remove the blade, see figs
27-28-29.
Fig 23-24
Table insert
B
Access door
Lower blade holder
16
Fig 25-26
Phillips screw
Fig 27-28-29
Upper blade holder