PERIODIC INSPECTIONS (cont)
NOTES (cont):
16. Replace flexible fuel tank supply hose at time of engine overhaul.
17. Maintain cable tensions specified in chapter 27.
18. Refer to list of vendor and Piper publications in the front of the maintenance manual for appropriate
subject manual part number.
19. Refer to Lycoming Service Bulletin 469.
20. The airborne auxiliary vacuum pump/motor (4A3-1) must be removed from service at 500 hours
operating time as indicated on the elapsed time indicator, or at l0 years of installed time in the aircraft,
whichever comes first.
100 Hour/Annual Inspection Report printed copies are available
through Piper service sales - under Piper part number 230 811.
refer to latest revision of Piper Parts Price List Aerofiche (last
card in set) for latest revision to this report.
21. If not already installed, add access panels per instructions in Chapter 51. See latest revision of Piper
Service Bulletin 977.
22. Special care should be taken to inspect stabilator control cables beneath aft baggage compartment
floor. Add access panels per instructions in Chapter 51 to ease this inspection.
PIPER AIRCRAFT
PA-28-236
MAINTENANCE MANUAL
—NOTE—
1B10
Interim Revision: February 15, 1995
5 - 21 - 00
Page 5 - 11