Propane Gas Supply Sizing; Carrying Handle - L.B. White CP400 Owner's Manual And Instructions

Tradesman construction heaters
Table of Contents

Advertisement

13. The heater must be installed so as not to interfere
with or obstruct normal exits, emergency exits, doors
and walkways.
14. Railing, fencing or suitable substitute materials must
be used to keep the heating equipment from any
people using and visiting the structure.
15. Eventually, like all electrical/mechanical devices, the
thermostat can fail. Thermostat failure may result in
an underheating condition. The thermostat should be
tested to make sure it turns the heater on and off
within a temperature differential of ±3°F.
The vaporization of propane is affected by several factors:
the surface area of the container, the liquid level of
propane, temperature surrounding the container, and the
relative humidity. All of these factors are specific to a site.
Therefore, a degree of experience and judgement is
required to select the proper propane supply.
Although experience is the best guide, the following
recommendations can be used as a starting point. The
table is based on experience in northern climates where
cold weather and high humidity are prevalent in the winter.
If more or less favorable conditions prevail at a specific site,
adjustments can be made on the basis of experience.
1. Locate accessory package with handle and screws.
2. Align handle to screws holes in case top. Install four
screws and tighten securely.
Note: The handle may be relocated to the side of the
top panel for heater stacking during storage. Do not
stack heaters more than two high.
16. Take time to understand how to operate and
maintain the heater by using this Owner's Manual.
Make sure you know how to shut off the gas supply to
the building and also to the individual heater.
Contact your fuel gas supplier if you have any
questions.
17. Any defects found in performing any of the service or
maintenance procedures must be eliminated and
defective parts replaced immediately. The heater
must be retested by properly qualified service
personnel before placing the heater back into use.

PROPANE GAS SUPPLY SIZING

Recommended Gas Supply
Propane Supply Tank:
500 gallon
1,000 gallon
If more than one gas supply container is used per heater,
the containers must be manifolded together to allow vapor
withdrawal simultaneously from multiple containers.
Manifold system shall be in accordance with NFPA 58.
FIG. 1
ALTERNATE
HANDLE HOLES
Heater(s)/Container(s):
1 heater per tank
2 heaters per tank

CARRYING HANDLE

8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents