Hose And Regulator Assembly; Connecting Regulator To Propane Gas Supply - L.B. White Workman CV225 Owner's Manual And Instructions

Convection construction heaters
Hide thumbs Also See for Workman CV225:
Table of Contents

Advertisement

-- If necessary, replace the parts or components
involved if the leak cannot be stopped.
-- Ensure all gas leaks have been identified and
repaired before proceeding.
9. A qualified service agency must check for proper
operating gas pressure upon installation of the heater.
10. Light according to instructions on heater or within
owner's manual.
11. Make sure the heater has the proper gas regulator for
the application. A regulator must be connected to the
gas supply so that gas pressure at the inlet to the gas
valve is regulated within the range specified on the
dataplate at all times. Contact your gas supplier, or
the L.B. White Co., Inc. if you have any questions.

HOSE AND REGULATOR ASSEMBLY

1. Apply a small amount of pipe thread sealant to
threads of rigid hose connection. Connect this end to
to regulator outlet. See Fig.1 Tighten securely.
2. Connect opposite end of hose with nut to safety
control valve at heater. See Fig.2. Tighten securely.
FIG. 1
APPLY SEALANT

CONNECTING REGULATOR TO PROPANE GAS SUPPLY

1. Remove protective cap from POL fitting. Do not
discard cap. Position regulator as shown.
2. Insert POL fitting into propane supply valve. See Fig.2.
Thread nut on fitting counterclockwise into propane
supply valve. Tighten nut securely with a wrench.
-- When storing or transporting the heater, ensure the
cap is pushed onto the POL fitting to prevent
damage or dirt entry into regulator.
8
12. This heater is configured for use with propane vapor
withdrawal only. Consult the heater's dataplate for the
gas configuration of the specific heater. Do not use
the heater in an propane liquid withdrawal system or
application. If you are in doubt, contact the L.B. White
Co., Inc.
13. Take time to understand how to operate and maintain
the heater by using this Owner's Manual. Make sure
you know how to shut off the gas supply to the building
and also to the individual heater. Contact your fuel gas
supplier if you have any questions.
14. Any defects found in performing any of the service or
maintenance procedures must be eliminated and
defective parts replaced immediately. The heater
must be retested by properly qualified ser vice
personnel before placing the heater back into use.
FIG. 2
FIG. 3
VENT ON REGULATOR WILL BE
DIRECTED DOWN
NUT HAS LEFT HANDED
THREADS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents