L.B. White TRADESMAN K70 Owner's Manual

Kerosene portable forced air heaters with built-in thermostat
Hide thumbs Also See for TRADESMAN K70:

Advertisement

Quick Links

TRADESMAN K70 & KI65
KEROSENE PORTABLE FORCED AIR HEATERS
HEATER SIZE: 70,000 AND 165,000 BTU/HR
IMPORTANT: Read and understand this manual before
assembling, starting, or servicing heater. Improper use
of heater can cause serious injury. Keep this manual for
future reference.
Safety Informa ion ............................................... 2
Unpacking ........................................................... 3
Fuels .................................................................... 4
Ventilation ............................................................ 4
Theory of Operation ............................................ 4
Assembly ............................................................. 5
Operation ............................................................. 5
Operation With Portable Generator ..................... 6
Storing, Transporting, or Shipping ....................... 6
(WITH BUILT-IN THERMOSTAT)
OWNER'S MANUAL
MODELS: CP070CK AND CP165DK
H.S.I. SERIES

TABLE OF CONTENTS

Save this manual for future reference.
Preventative Maintenance Schedule ................... 7
Troubleshooting ................................................... 7
Service Procedures ............................................. 9
Wiring Diagram .................................................. 15
Replacement Parts ............................................ 15
Technical Service .............................................. 15
Accessories ....................................................... 15
Warranty ..............................................Back Cover

Advertisement

Table of Contents
loading

Summary of Contents for L.B. White TRADESMAN K70

  • Page 1: Table Of Contents

    TRADESMAN K70 & KI65 KEROSENE PORTABLE FORCED AIR HEATERS (WITH BUILT-IN THERMOSTAT) OWNER’S MANUAL MODELS: CP070CK AND CP165DK HEATER SIZE: 70,000 AND 165,000 BTU/HR H.S.I. SERIES IMPORTANT: Read and understand this manual before assembling, starting, or servicing heater. Improper use of heater can cause serious injury.
  • Page 2: Safety Informa Ion

    SAFETY INFORMATION e) At no time shall more than one dayʼs supply of heater fuel be stored inside a building in the vicinity of the heater. Bulk fuel storage WARNING: This product con- shall be outside the structure. tains and/or generates chemicals f) All fuel storage shall be located a minimum known to the State of California of 25 feet (762 cm) from heaters, torches,...
  • Page 3: Unpacking

    SAFETY INFORMATION Continued 18. Never move, handle, refuel, or service a hot, Hot Air operating, or plugged-in heater. Outlet Fan Guard 19. Never attach duct work to front or rear of heater. 20. Never attach heater to external fuel tank. 21.
  • Page 4: Fuels

    FUELS VENTILATION WARNING: Use only kero- WARNING: Provide a fresh air sene, #1/#2 diesel/fuel oil, JET A opening of at least three square or JP-8 fuels to avoid risk of fire or feet (2,800 square cm) for each explosion. Never use gasoline, oil 100,000 Btu/hr rating.
  • Page 5: Assembly

    ASSEMBLY (FOR 165,000 BTU MODEL ONLY) These models are furnished with wheels and a handle. Some models are furnished with a second handle also. Wheels, handle(s), and the mounting hardware are found in the shipping carton. Tools Needed • Medium Phillips Screwdriver •...
  • Page 6: Operation With Portable Generator

    Ground Lug Alternator Copper or Brass Grounding Point Ground Wire (#10 AWG - Stranded- Copper) Figure 7 - Typical Generator Grounding Method (Generator construction may vary from that shown) 114278-01C...
  • Page 7: Operation

    PREVENTATIVE MAINTENANCE SCHEDULE WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. Item How To How Often Fuel tank See Storing, Transporting, or Flush every 150-200 hours of operation or as needed Shipping, page 6 Air output and lint filters See Air Output, Air Intake, and...
  • Page 8 TROUBLESHOOTING Continued FAULT CONDITION POSSIBLE CAUSE REMEDY Motor starts and runs but heater 1. No fuel in tank 1. Fill tank with kerosene does not ignite 2. Pump pressure incorrect 2. See Pump Pressure Adjust- ment, page 10 3. Dirty fuel filter 3.
  • Page 9: Service Procedures

    SERVICE PROCEDURES WARNING: To avoid risk of burn and electrical shock, never attempt to service heater while it is plugged in, operating, or hot. UPPER SHELL REMOVAL 1. Remove screws along each side of heater using 5/16" nut-driver. These screws attach upper and lower shells together.
  • Page 10 SERVICE PROCEDURES Continued Figure 13 - Air Output, Air Intake, and Lint Filters, 165,000 Model Only 114278-01C...
  • Page 11 SERVICE PROCEDURES Continued IGNITOR 1. Remove upper shell and fan guard (See Upper Shell Removal, page 9). 2. Remove fan (see page 9). 3. Remove 4 side cover screws with a 5/16" nut driver. Remove side cover (see Figures 16 or 17, page 10).
  • Page 12 SERVICE PROCEDURES Continued Air Line Fuel Line Hose Hose Figure 20 - Removing Air and Fuel Line Hoses (70,000 Btu Model Only) Combustion Chamber Nozzle Adapter Bracket Nozzle/ Adapter Air Line Assembly Hose NOZZLE ASSEMBLY 1. Remove upper shell (see Upper Shell Re- moval, page 9).
  • Page 13 SERVICE PROCEDURES Continued Pump End Cover Barb Fitting Barb Fitting Air Hose 70,000 Btu 165,000 Btu Models Models Figure 24 - Air Hose to Barb Fitting 114278-01C...
  • Page 14: Specifications

    SERVICE PROCEDURES IGNITION CONTROL ASSEMBLY Continued WARNING: High voltage! 1. Unplug heater. 2. Remove side cover screws (4) using 5/16" nut- driver to expose ignition control assembly. 3. Remove fuse cover (see Figure 29). 4. Remove fuse from fuse clips (see Figure 29). 5.
  • Page 15: Wiring Diagram

    Note: Use only original replacement parts. This dealer or service center. If they can not supply will protect your warranty coverage for parts these accessories or parts, contact L.B. White at replaced under warranty. 1-800-345-7200 for referral information. PARTS UNDER WARRANTY L.B.
  • Page 16: Illustrated Parts Breakdown And Parts List

    ILLUSTRATED PARTS BREAKDOWN MODEL CP070CK 114278-01C...
  • Page 17 PARTS LIST MODEL CP070CK This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. NO.
  • Page 18 ILLUSTRATED PARTS BREAKDOWN MODEL CP165DK 114278-01C...
  • Page 19 PARTS LIST MODEL CP165DK This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. NO.
  • Page 20 ILLUSTRATED PARTS BREAKDOWN BURNER HEAD ASSEMBLY NO. PART NO. DESCRIPTION QTY. 130-22961 Nozzle Assembly CP070CK 130-21926 Nozzle Assembly CP165DK 120-21933 Ignitor Kit 130-21928 Screw 130-21917 Nozzle Adapter Bracket 130-22962 Nozzle Adapter 130-22963 Washer 114278-01C...
  • Page 21 ILLUSTRATED PARTS BREAKDOWN MOTOR AND PUMP ASSEMBLY FOR CP070CK NO. PART NO. DESCRIPTION QTY. 120-22965 Motor 130-20857 Pump Body 130-20858** Insert 130-20859** Rotor 130-20876 Pump End Cover 130-20981*** Lint Filter 130-20878*** Intake Filter 130-20881 Filter End Cover 130-20813 Screw, #10-32 x 1" 130-20917 ∞...
  • Page 22 ILLUSTRATED PARTS BREAKDOWN MOTOR AND PUMP ASSEMBLY FOR CP165DK NO. PART NO. DESCRIPTION QTY. 120-22965 Motor 130-20857 Pump Body 130-20814 Screw, #10-32 x 5/8" 130-20858** Rotor Insert 130-20859** Pump Rotor 130-20877 Pump End Cover 130-20879*** Intake Filter 130-20882 Filter End Cover 130-20915 ∞...
  • Page 23 ILLUSTRATED PARTS BREAKDOWN WHEELS AND HANDLE PARTS LIST, MODEL CP165DK ONLY (Left or Right Side) NO. PART NO. DESCRIPTION QTY. 130-24787 Handle Kit (If Equipped) 130-20853 Screw, #10-24 x 1 " 6 or 8 130-24791 Wheel Frame Support 130-24788 Cord Cleat Kit (Left or Right) (If Equipped) (Contains 2 Cleats, 4 Nuts and 4 Bolts) 130-24790 Pneumatic Wheel Kit (Contains 2 Wheels,...
  • Page 24: Warranty

    WARRANTY EQUIPMENT L.B. White Co., Inc. warrants that the component parts of its equipment are free from defects in material and workmanship, when properly operated and maintained in accordance with the maintenance instructions, safety guides and labels contained with each unit. If, within 12 months from the date of purchase by the end user, any component is found to be defec- tive, L.

This manual is also suitable for:

Tradesman ki65Cp070ckCp165dk