Jumper Settings for ELECTH-HPUMP and HE-HG:

Jumper
ELECTH
HPUMP
ELECTH
HPUMP
HG
HE
HG
HE

Mounting:

1. Open the ZTS-100 by pushing the hook (Figure 5)
2. Install AAx4pcs batteries if using battery power (Alkaline batteries are
recommended)
3. Check the polarity of the batteries and the "+/-" marks inside the battery
compartment
4. Connect 24Vac power if using 24Vac power source
5. Place the cables at the hole near the terminal block
6. Insert 2 pieces of wall anchors into the holes of the wall
7. Fasten the thermostat with 2 pieces of long screws through the 2 mounting holes
(Figure 6)
8. Install the top housing by hooking the bottom (Figure 6)
Figure 5. Open ZTS-100
Set to ELECTH for non heat pump system (Default)
Set to HPUMP for heat pump system
Set to HG for Gas heat-fan controlled unit (Default)
Set to HE for Electrical heat-fan controlled unit
Function Description
Figure 6. Install the top housing