Defrost Indication
Step
Procedure / Description
DEFROST icon will be displayed at Home
page if temperature below 41 F/5 C.
1
All heaters will be forced On, except in
cool mode.
Out of Temperature Range Indication
Step
Procedure / Description
HI icon will be displayed on LCD if
temperature excess the measurement
ranges 99 F/40 C.
1
All heaters will be forced Off.
Cooler will turn on if running cool mode.
LO icon will be displayed on LCD if
temperature below the measurement
ranges 32 F/0 C.
2
All heaters will be forced On, except in
cool mode.
Energy Saving Mode
Step
Procedure / Description
User can enable/disable energy saving
mode by using Z-Wave BASIC set
command only.
=> Enable energy saving mode
Basic set value = 0x00 (off mode)
(energy saving mode will be mapped to
1
off mode)
=> Disable energy saving mode
Basic set value = 0xFF (resume mode)
(comfort mode will mapped to resume
mode)
o
o
o
o
TU
o
o
TU
TU