Temperature Control Lever; Adjustment Of The Blend Air Damper - Mitsubishi Montero 1987 Service Manual

Table of Contents

Advertisement

HEATERS
- Service
Adjustment
Procedures
24-7
TEMPERATURE CONTROL
LEVER
1. Move the temperature
control
lever from
its extreme
left
position
to its extreme
right position
and check to be sure
that it moves
correctly
and smoothly
to each position.
2. Then move the temperature
control
lever to the extreme
left position,
and check to be sure that warm air does not
come
out when
the blower
is operated.
3.
If the air flow is not correct
in the above step, adjust
the
temperature
control
wire.
h?*
I
Water valve lever
-
7
Blend
air d
Adjustment
of the Blend Air Damper
I.
Move the warm water flow control
lever to the extreme
left
position.
2. Disconnect
the water valve control
wire from the blend air
damper
lever and the heater
unit's
clip.
3.
Remove
the water
valve cover.
4.
Unfasten
the
clip
of the
blend
air damper
lever,
and
disconnect
the link for water valve lever from the blend air
damper
lever.
5. Push the water valve lever all the way inward
so that the
water
valve is at the closed
position.
6. Turn the blend air damper
lever all the way in the direction
of the arrow so that the blend
air damper
is completely
closed
at the lower
most
position.
7. Attach
the end of the link for the water valve lever to the
blend
air damper
lever.
8. Install
the water
valve
cover.
9. After connecting
the water valve control
wire to the blend
air damper
lever, connect
to the clip part of the heater unit.
Caution
Be careful that the lever does not move when clipping.
10. Check
to be sure
that
the
temperature
control
lever
operates
smoothly
at each position.
Also check to be sure
that the blend
air damper
is completely
closed
when the
temperature
control
lever
is moved
to the extreme
left
position
and the extreme
right
position.
1 STB Revision