AIR-CONDITIONING-Service
Adjustment Procedures
SERVICE ADJUSTMENT
PROCQDURES
24-29
N24FDAD
MANIFOLD
GAUGE SET INSTALLATUON
Discharge
W
gauge
Suction
gauge
Suction
gauge
valve
Manifold Gauge Valves should be closed
when
connecting
the manifold gauge set to the service port of the
compressor and the discharge hose. The suction gauge valve at the left is opened to provide a passage between
the suction gauge and the center manifold outlet. The discharge gauge valve at the right is opened to provide a
passage between the discharge pressure gauge and the center manifold outlet.
Detailed instructions for proper use of the gauge set manifold are contained in the text covering each test and
service operation employing these gauges.
Suction Gauge; the left side of the manifold set is calibrated to register 0 to-100
kPa (0 to 30 in. of vacuum) and
0 to 1000 kPa (0 to 150 psi). This gauge is connected to the suction port of the compressor.
Discharge Gauge; the right of the manifold
set is calibrated
to register 0 to 2100 kPa (0 to 300 psi). For all
tests this gauge is connected
to the discharge
port of the system.
Center Manifold Outlet provides the necessary connection for a long service hose used when discharging the
system, using a vacuum pump to "pull a vacuum"
before charging the system, and for connecting the supply of
refrigerant when charging the system
glass
-
2OW724
N24FEAE
The receiver drier assembly consists of; Drier reservoir, Refriger-
ant level sight glass and Fusible plug.
To Test the Receiver
Drier
(1) Operate the unit and check the piping temperature
by
touching the receiver drier outlet and inlet.
(2) If there
is a difference
in the
temperatures,
the
received
drier is restricted.
Replace the receiver
drier.
SIGHT
GLASS
REFRlGERANT
LEVEL TEST
The sight glass is a refrigerant level indicator. To check the refrigerant
level, clean the sight glass and start the
vehicle engine. Push the air conditioner button to operate the compressor, place the blower switch to high and
move the temperature
lever to extreme left.
After operating for a few minutes in this manner, check the sight glass.
(1) If the sight glass is clear, the magnetic clutch is engaged, the compressor discharge line is warm and the
compressor inlet line is cool; the system has a full charge.
(2) If the sight glass is clear, the magnetic clutch is engaged and there is no significant temperature
difference
between compressor inlet and discharge lines; the system has lost some refrigerant.
(3) If the sight glass is clear and the magnetic clutch is disengaged; the clutch is faulty or, the system is out of
refrigerant. Perform low pressure switch test to determine condition. Check low pressure switch and clutch coil
for electrical continuity.