Mitsubishi Montero 1987 Service Manual page 242

Table of Contents

Advertisement

24-6
HEATERS
- Service
Adjustment
Procedures
(2) Turn the mode selection
damper
lever all the way in the
direction
of the arrow.
(3) Pull the "VENT"
damper
lever completely
downward
and move
the "VENT"
damper
to the position
(not
visible)
shown
in the figure.
(4) Attach the end of the link for the "VENT"
damper
to the
:
mode
selection
damper
lever.
3. Adjust
the "FOOT/DEF"
damper
as described
below.
(1) Unfasten
the clip of the mode
selection
damper
lever,
and disconnect
the link for the "FOOT/DEF"
damper
from the mode
selection
damper
lever.
(2) Turn the mode selection
damper
lever all the way in the
direction
of the arrow.
(3) Pull the "FOOT/DEF"
damper
lever completely
upward
and move
the "FOOT/DEF"
damper
to the position
shown
in the figure.
(The packing
should
contact
the
case.)
NOTE
Confirmation
can be made that the "FOOT/DEF"
damp-
er is raised upward
through
the defroster
blower
outlet
of the heater
unit (with defroster
duct disconnected).
(4) Attach
the end of the link for the "FOOT/DEF"
damper
to the mode
selection
damper
lever.
NOTE
When attaching
it, pull the lever end (A in the figure)
in
the direction
of the arrow.
4.
Referring
to the section
which
explains
the adjustment
of
the mode
selection
control
wire, connect
the control
wire
to the mode
selection
damper
lever.
1 STB Revision

Advertisement

Table of Contents
loading

Table of Contents