Mitsubishi Montero 1987 Service Manual page 257

Table of Contents

Advertisement

AIR-CONDITIONING
-Specifications
SPECIFICATIONS
GENERAL
SPECIFICATIONS
24-2 1
N24CA-
Items
Specifications
Compressor
Model
6P148lnclined-plate
type
No. of cylinders
and displacement
6 cylinders
6,148 (208,216)
cc. (U.S.fl. oz., Imp.fl.02.)
Refrigeration
unit lubricant
cc. (U.S.fl. oz., Imp.fl.oz.)
DENS0 oil 6
110 (3.7,3.9)
Protective
equipment
OFF: 1 .O (22)
ON:4.5 (39)
Cycling clutch switch
"C("F)
OFF:210 (30)
ON:230 (33)
Low pressure
switch
kPa (psi)
OFF: 113 (235)
ON:106(222)
Water temperature
switch
"C ("F)
Air temperature
thermostat
Freezor prevention
"C ("F)
OFF:3 (37.4)
ON:5 (41)
Burn out temperature
106 (222)
Fusible plug
"C ("F)
R-l 2
600-900 (1.3-2.0)
Refrigerant
and quantity
g (Ibs.1
SERVICE SPECIFICATIONS
N24CE-
Items
Specifications
Standard value
Drive belt deflection
mm (in.)
17.20 (.7-.8)
Pressure
plate to rotor clearance
mm (in.)
0.4-0.7
(.02-.03)
TORQUE SPECIFICATIONS
N24CG
Items
Nm
ftlbs.
Suction hose to cooling unit
30-35
22-25
Liquid pipe to cooling unit
12-15
9-l 1
Liquid pipe to receiver drier
12-15
9-l 1
Suction hose to suction hose
30-35
22-25
Liquid pipe to liquid pipe
12-15
9-l 1
Liquid pipe to condenser
20-25
15-18
Suction hose to compressor
30-35
22-25
Discharge hose to compressor
20-25
15-18
Discharge hose to liquid pipe
20-25
15-18
Compressor shaft nut
15-17
11-13
Through bolt
25-26
18-20
/ STB Revision