It is possible not to set the stop time by setting the readout to OFF. Use key 1 or 2 to
scroll the timetable band to find OFF, which appears at the end of the 24-hour cycle.
Confirm by pressing the SET key.
Press key 2 to select the day of the week. Press key 1 and select ON to activate the first
operating cycle on the selected day, or select OFF to deactivate it.
Proceed for the three days of the week – Friday, Saturday and Sunday.
Confirm by pressing the SET key.
Press key 1 or 2 to set the required power level during the first operating cycle.
Confirm the power setting by pressing the SET key.
Press key 1 or 2 to set the required room temperature (example in °C) during the first
operating cycle.
Confirm the temperature by pressing the SET key.
Programming automatically passes to the second operating cycle. To continue
programming for the second cycle, proceed in sequence with the steps given for the
first cycle. The number 2 appears on the display, indicating the second operating cycle.
If you do not want to program a second cycle, set START and STOP of the second
programming cycle to OFF.

6.8 ENERGy SAvING

When the ENERGY SAVING mode is enabled, automatic startup/ignition and shutdown of the stove is activated at temperature values set by the user
through the STOP and START functions.
The temperature value selected 2, 4 or 6 °F (1, 2 or 3 °C ) in STOP function or selected in START function with negative values -2, -4 or -6 °F (-1, -2
or -3 °C) defines the value from which the Energy Saving mode will either increment or deduct from the room temperature set.
The operating principle is as follows:
When the room temperature measured by the room sensor, or the external thermostat reaches the temperature value programmed by the user, the
stove automatically goes to power level 1 (readout "OK" on the display).
If the room temperature continues to rise with operation at power level 1 up to the value set on the STOP function (e.g. +4 °F / +2 °C compared to
the programmed temperature), the stove shuts down and goes into the stand-by mode.
When the room temperature measured by the room sensor, the external thermostat drops to the temperature value set by the user on the START
function (e.g. -6 °F / -3 °C compared to the programmed temperature), the stoves starts a new ignition phase and goes back to the power level
previously set by the user.
a
The stove only restarts when the temperatures measured on the actual stove allow its use in all safety.
If the STOP and OFF functions are enabled, upon reaching the programmed room temperature, the stove will operate in the conventional way by
going to power level 1 without shutting down.
Likewise with the START and OFF enabled the stove does not start the startup/ignition phase after automatic shutdown and will remain off.
Select the ENERGY SAVING menu.
Press the MENU key, then using the SELECT MENU key select the ENERGY SAVING
function and confirm by pressing the SET key.
Select the value to be set for shutdown temperature.
Press the SELECT MENU key and then select the temperature set point 2, 4 or 6 °F (1,
2 or 3 °C) or disable the function by selecting OFF.
Confirm by pressing the SET key.
Description of activity
Description of activity
H07029330 / DT2001081 – 02
oFF
SUON
02
25°
17:20
ENERGY SAVING
ENERGY
STOP
Display
STOP
WEEK END
PROGRAM 1
DAYS WEEK END
LIT 1
SET WEEK END
POWER 1
SET TEMP
ROOM 1