Check Stationary Stop Switch

Stationary stop switch is located on governor control
bracket.
1. Push down on wire retainer and remove stop
switch wire.
2. Connect one meter lead to engine ground and
other lead to stop switch wire retainer, Fig. 38.
3. Move control lever to "RUN" position. There
should be no continuity.
4. Move control lever to "STOP" position. There
should be continuity, Fig. 38.
14
2
Fig. 38 – Checking Stationary Stop Switch