L200/L201/L100/L101
Tube Valve Holder Rear / Tube Valve Holder Front
Ink Tubes
Grooves
Tube Valve Holder Front
1
2
Tube Valve Holder Rear
C.B.P-TITE SCREW 3x6 (5.0 ~ 6.0 kgf·cm)
When installing the Tube Valve Holder Front, align the blue
lines (the red lines for L100/L101) of the ink tubes in the same
direction as shown in the figure above, and route them through
the grooves of the Tube Valve Holder Front.
Tighten the screws in the order indicated in the figure above.
Tube Guide Plate
Clamps (x2)
Joint side
190 ± 1 mm
257 ± 1 mm
335 ± 1 mm
420 ± 4.2 mm or 10% tolerance
Tube Guide Plate
Ink Tube Guide 2nd
Positioning hole and dowel
Before installing the Tube Assy, align the positioning holes (x2) of the Tube Guide Plate with the dowels (x2) of the Ink Tube Guide 2nd.
When installing the Tube Assy, attach the Clamps (x2)/Tube Holder Top/Tube Holder Lower/Tube Guide Plate in the positions shown in the
figure above.
When installing the Tube Assy, align the red lines of the ink tubes in the same direction as shown in the figure above, and attach them without
any slack.
Disassembly/Assembly
Tube Holder Top / Tube Holder Lower
Yellow
Magenta
Cyan
Black
Ink Tubes
Tube Holder Top/
Tube Holder Lower
C.B.P-TITE SCREW 2.6x16 (5.0 ~ 6.0 kgf·cm)
Align the positioning holes (x2) of the Tube Guide Plate with
the dowels (x2) of the Tube Holder Top.
Route the ink tubes while avoiding the rib of the Tube Holder
Lower to prevent the tubes from getting caught by the tube holders.
Make sure to route the ink tubes as shown in the figure above
when installing the Tube Holder Top/Tube Holder Lower.
Route the ink tubes over the films of the Adapter Assy.
Tube Assy
Tube Holder Top/
Tube Holder Lower
Tube Holder Top/
Black
Magenta
Tube Holder Lower
Adapter Assy
side
Yellow
Cyan
Tube Assy
Joint
Tube Holder Top
Film
Film
Adapter Assy
Tube Guide Plate
Positioning hole
and dowel
Tube Holder Lower
Ink Tubes
Rib
Be careful not to damage or peel off the film of the Adapter Assy.
When installing the ink tubes to the Adapter Assy, insert the ink
tubes with their red lines facing upward as shown in the figure
above.
Tube Guide Plate
Ink Supply Tank
Assy side
Ink Supply Tank Assy
Clamps (x2)
When installing the Valve Assy, attach the Clamp on the position shown in the figure above.
When installing the Valve Assy, align the blue lines of the ink tubes (the red lines for L100/L101) in the same direction as shown in the figure
above, and route them through the holes of the Ink Supply Tank Assy.
When installing the Valve Assy, secure it with the hooks (x2) of the Ink Supply Tank Assy.
Details of Disassembling/Reassembling by Parts/Unit
Adapter Assy
Valve Assy
side
Opening for Ink Tubes
Valve Assy
side
Valve Assy
Valve case
Clamp
165 ± 1 mm
L200/L201: 310 mm
L100/L101: 290 mm
Valve Assy
Hook
Ink Supply Tank Assy
Revision A
Joint
Front
Joint
Tube Assy
side
Back
Joint
Tube Assy
side
Align the red lines and blue lines (the other red lines for L100/
L101) respectively in the same direction as shown in the figure
above, and insert them to the joint to the full to its base.
Be careful not to damage the ink tubes and joint.
Length of Ink Tube
L200/L201
L100/L101
Joint
Black
400 mm
380 mm
Magenta
370 mm
350 mm
Yellow
345 mm
325 mm
Cyan
345 mm
325 mm
Tube Assy
side
Valve case
Ink Tube
Hole
28
Confidential