Counting - Sartorius SIWABBP Operating Instructions Manual

Hide thumbs Also See for SIWABBP:
Table of Contents

Advertisement

Counting Application
Z
Counting Application Z
With the Counting application, you can
determine the number of parts which
each have approximately equal weight.
Characteristics
– Save the reference weight "wRef" from
the weighing platform
®
Signum
3 only:
– Enter the average piece weight "wRef"
via the keypad
®
Signum
3 only:
– Enter the reference sample quantity
"nRef" via the keypad
– Enter reference sample weight using
a barcode scanner
– Automatic reference sample updating
– Counting with two weighing platforms
– Activate Info mode via the I key
– Toggle the display between quantity
and weight via the W key
– Define the level of accuracy (display
resolution) applied when a calculated
reference sample quantity is saved
– Automatic taring of container weight.
Configured in Setup under:
Appl: Z: 3.7.
(autotare first weigh)
®
Signum
3:
APPL: A.Tare
– Automatic initialization when the
scale is switched on. The indicator is
initialized with the most recently used
values for reference sample quantity
"nRef" and reference sample weight
"wRef." Configured in Setup under:
Appl: Z: 3.8.
(Start App. with last values)
®
Signum
3:
APPL: A.start
– Exit application, delete parameters:
The value of the reference sample
weight in the reference memory remains
active until the application is changed
or the value is overwritten or deleted
via the c key. The reference sample
weight also remains saved after the
scale is turned off.
52
Signum 1-2-3
®
Signum
3 only:
You can assign different functions to
the c key for deleting applications.
When you clear applications, you can
delete either the data stored for all
applications or just the data stored for
the active application. Configured in
Setup under:
APPl: sel.cf.
(sel.
function key c in
CF
applications)
– Tare function:
1) If you store a tare (weight value)
by pressing the ) key, you can later
enter a value manually. The value you
enter is added to the stored tare value.
Setting: menu code 3.25.1 (factory
setting)
2) A value entered manually overwrites
a stored tare value (weight value). If
you enter a value manually, a tare value
(weight value) stored later overwrites
the manually entered value. Setting:
menu code 3.25.2
Configured in Setup under:
®
Signum
2
Z
Appl:
nm: 3.25.;
Signum
®
3
Appl: tare. f: 3.25.
– Restore factory default settings.
Configured in Setup under:
: 9.1.
Z
Appl:
®
Signum
3:
APPL: def.app: 9.1.
Before the quantity on the platform
can be calculated, the average piece
weight (reference sample weight)
must be entered in the application.
There are three ways to enter this
value in the program:
– Calculation:
– P lace the number of parts defined as
the reference sample quantity on the
weighing platform and calculate the
average piece weight by pressing the
O key.
– A lternatively, using the r key, you
can place any number of parts on the
weighing platform, enter the number
of parts using the keypad, and then
press the
key.
O
How the reference weight is calculated
depends on the application setting for
resolution. The value is either rounded
off in accordance with the display
resolution, or saved with 10-fold
or 100-fold resolution, or with the
maximum internal resolution of the
weighing platform.
®
Signum
3 only:
– Enter a reference sample weight (i.e.,
the weight of one piece) using the
keypad and saving it with the
– Enter the reference sample weight using
a barcode scanner.
After initialization, you can use the
connected weighing platform to count
parts.
The initial application values remain
active until deleted by pressing the c
key or until overwritten by a new value.
They remain saved after the scales are
switched off.
O
key.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents