Clean Feature Minutes - Whirlpool WHES33 Installation And Operation Manual

Demand controlled water softener
Table of Contents

Advertisement

Customizing Features / Options
CLEAN / CLEAR WATER IRON REDUCTION
This feature is beneficial on water supplies containing
ferrous (clear water) iron. The default setting is OFF.
When this feature is set to ON, an additional back-
wash and fast rinse cycle will occur first, preceding
the normal regeneration sequence. This provides
extra cleaning of the resin bed before it is regenerat-
ed with the salt brine. To conserve water set this fea-
ture OFF if your water supply does not contain iron or
sediments.
1. Press and hold the PROGRAM button until the
screen in Figure 37 is displayed. Once in this dis-
play, press the PROGRAM button twice and one of
the two displays in Figure 38 is shown.
s
2. Press the
UP or
OFF.
3. Press the PROGRAM button four times to return to
the normal run display.

CLEAN FEATURE MINUTES

The Clean / Clear Water Iron Reduction feature
(described above) may be adjusted, from 1 to 15 min-
utes in length. To change this cycle time, use the UP
button to increase the time, or the DOWN button to
shorten the time. The default value for this feature is
2 minutes.
1. Press and hold the PROGRAM button until the
screen in Figure 37 is displayed. Once in this dis-
play, press the PROGRAM button three times and
the display in Figure 39 is shown.
s
2. Press the
UP or
number of minutes.
3. Press the PROGRAM button three times to return
to the normal run display.
(Models WHES30 & WHES33)
FIG. 37
DOWN buttons to set ON or
FIG. 38
FIG. 39
DOWN buttons to set the
MAXIMUM DAYS BETWEEN REGENERA-
TIONS
The water softener automatically controls regenera-
tion frequency. This provides the greatest operating
efficiency and, under most conditions, this feature
should be left in this automatic mode. However, you
may modify this feature if you want to force a regen-
eration every set number of days. For example, if
your water supply contains clear water iron, you may
want the softener to regenerate every few days to
keep the resin bed clean. The maximum days
between recharges may be set from 1 to 15 days, as
follows:
NOTE: The softener will recharge on its own if need-
ed, even if it is before the set number of days.
1. Press and hold the PROGRAM button until the
screen in Figure 37 is displayed. Once in this dis-
play, press the PROGRAM button four times and
the display in Figure 40 is shown.
2. Press the
UP or
number of days.
3. Press the PROGRAM button two times to return to
the normal time of day screen.
12 OR 24 HOUR CLOCK
At the default setting, all clock displays are shown in
12 hour time format (AM and PM). If 24 hour time
format is desired, follow the steps below:
1. Press and hold the PROGRAM button until the
screen in Figure 37 is displayed. Once in this dis-
play, press the PROGRAM button five times and
one of the two displays in Figure 41 is shown.
2. Press the
UP or
time format.
3. Press the PROGRAM button once again, to return
to the normal time of day screen.
18
FIG. 40
s
DOWN buttons to set the
FIG. 41
s
DOWN buttons to set the

Advertisement