Carrier Infinity ICS 58MVC 100 Series Installation Instructions Manual page 55

Direct vent 4-way multipoise condensing gas furnace
Hide thumbs Also See for Infinity ICS 58MVC 100 Series:
Table of Contents

Advertisement

d.Jumper R
and W/W1 thermostat connections
on control
to start furnace.
e. Turn
medium-heat
adjusting
screw
counterclockwise
(out) to decrease
manifold
pressure
or clockwise
(in) to
increase
manifold
pressure.
NOTE:
DO NOT
set medium-heat
manifold
pressure
less than
1.3- in. wc or more than 1.7-in.
wc for natural
gas.
UNIT
DAMAGE
HAZARD
Failure
to follow
this caution
may result in reduced
furnace
life.
DO NOT bottom out gas valve regulator adjusting screws.
This can result in unregulated manifold pressure and result
in excess over-fire and heat exchanger failures,
NOTE:
If orifice hole appears
damaged
or it is suspected
to have
been
redrilled,
check
orifice
hole with
a numbered
drill bit of
correct
size.
Never
redrill
an orifice.
A burr-free
and squarely
aligned
orifice
hole is essential
for proper
flame characteristics.
(See Fig. 61.)
f. Move setup switch
SW4-2
to OFF position
after com-
pleting
medium-heat
adjustment.
g. Jumper
R and W/WI
and W2 thermostat
connections
on
furnace control.
(See Fig. 33.) This keeps furnace locked
in high-heat
operation.
h. Turn high-heat
adjusting
screw
counterclockwise
(out)
to decrease
manifold
pressure
or clockwise
(in) to in-
crease manifold
pressure.
NOTE:
DO NOT
set high-heat
manifold
pressure
less than
3.2-in.
wc or more than 3.8-in.
wc for natural
gas.
i. Remove
jumpers
R to W/WI
and R to W2.
j. Wait for blower
off-delay
to finish
then reset
l15-v
power to furnace.
k. Jumper
R and W/WI
thermostat
connections
on control
to start furnace.
1. Wait for the blower to turn ON then check low-heat
mani-
fold pressure.
It should be between
.5 to .6-in. wc. This
setting should
not require
adjustment
but if it does re-
move the low-heat
adjustment
cap (See Fig. 60) and turn
the low-heat
adjusting
screw clockwise
(in) to decrease
manifold
pressure
or counterclockwise
(out) to increase
manifold
pressure.
You will only
have
15 minutes
to
make an adjustment
if needed.
If you need more time then
move setup switch SW1-2
on control center to ON posi-
tion (See Fig. 33).
NOTE:
DO NOT set low-heat
manifold
pressure
before setting
medium-heat
manifold
pressure.
DO NOT set low-heat
manifold
pressure
less than
.5-in.
wc or more
than .6-in.
wc for natural
gas.
m. When correct
manifold
pressures
are obtained,
replace
caps that
conceal
gas valve
adjustment
screws.
Main
burner
flame
should
be clear blue, almost transparent.
(See Fig. 62.)
n. Remove
jumper
across R and W/Wl.
If necessary
move
setup switch
SWI-2
to the OFF position.
3. Verify natural
gas input rate by clocking
gas meter.
NOTE:
Be sure all pressure
tubing,
combustion-air
and vent
pipes,
and burner
enclosure
front
are in place
when
checking
input by clocking
gas meter.
a. Calculate
high-altitude
adjustment
(if required).
UNITED
STATES
At altitudes
above 2000 ft. (609.6M),
this furnace
has
been
approved
for 2 percent
derate
for each 1000 ft.
(304.8M)
above sea level. See Table 11 for derate multi-
plier factor and example.
CANADA
At installation
altitudes
from 2000 to 4500 ft. (609.6
to
1371.6M),
this furnace
must be derated
5 percent
by an
authorized
Gas Conversion
Station or Dealer. To determ-
ine correct
input rate for altitude,
see example
and use
0.95 as derate multiplier
factor.
EXAMPLE:
80,000
BTUH
HIGH-HEAT
INPUT
FURNACE
INSTALLED
AT 4,300 ft. (1310.6M).
Furnace
Input Rate at Sea Level X Derate Multiplier
Fact-
or = Furnace
Input Rate at Installation
Altitude
80,000
X 0.91 = 72,800
b. Reinstall
burner
box cover.
NOTE:
Clocking
gas input
rate MUST
always
be performed
with the burner
box cover INSTALLED.
c. Check
that gas valve
adjustment
caps
are in place for
proper input to be clocked.
d. Obtain average heat value (at altitude) from local gas sup-
plier.
NOTE:
Be sure heating
value
of gas used for calculations
is
correct
for your
altitude.
Consult
local
gas utility
for altitude
adjustment
of gas heating
value.
e. Check
and
verify
orifice
size
in
furnace.
NEVER
ASSUME
THE
ORIFICE
SIZE.
ALWAYS
CHECK
AND VERIFY.
f. Turn off all other gas appliances
and pilots.
g. Move setup switch SW4-2
to ON position.
(See Fig. 33.)
This keeps furnace locked
in medium-heat
operation.
BURNER
ORIFICE
Fig. 61 - Burner
Orifice
A93059
55