Carrier Deluxe 58MVP Product Data

Carrier Deluxe 58MVP Product Data

Deluxe 4-way multipoise direct-vent variable-speed deluxe condensing gas furnace

Advertisement

Copyright 2004 Carrier Corporation
Product
Data
Deluxe 4-Way Multipoise
Direct-Vent Variable-Speed
Deluxe Condensing Gas Furnace
Input Capacities: 40,000 thru 120,000 Btuh
Infinity™ 96
Model 58MVP
Series 170
Comfort Heat™ technology,
the ultimate in
heating comfort . . .
The Carrier Infinity 96 with
ComfortHeat technology achieves
the optimum combination of comfort
and efficency.
The Infinity 96 achieves industry-
leading ultra-high efficiency at up to
96.6 percent Annual Fuel
Utilization Efficiency (AFUE).
Efficient performance is enhanced
through the variable-speed
design. To maintain ideal comfort,
ComfortHeat technology automati-
cally adjusts the heating level, maxi-
mizing the use of low heating levels
that produce near silent furnace opera-
tion while meeting the exact heating
needs. This unit is designed to keep the
indoor temperature within 1 degree of
the thermostat setpoint. Because it op-
erates in low heat most of the time, the
Infinity 96 uses up to 80% less power
than single-capacity furnaces.
In addition to providing ultimate com-
fort, the Infinity 96 has a sealed com-
bustion system. This system brings
combustion air from outdoors to the
furnace and vents flue gases safely
outside the home. Because it is sealed,
operational noise is minimal. A sealed
combustion system also means fewer
cold drafts and less air infiltration.
Quality materials are the key behind the
Infinity 96's outstanding performance.
Carrier stands behind quality. We offer
lifetime warranty protection* on the
heat exchangers, the heart of the
Infinity 96. The rest of the unit is
backed by a limited 5-year warranty.
The Infinity 96 is available in 6
heat/airflow combinations. The unit
has a 4-way multipoise design and can
Form 58MVP-11PD

Advertisement

Table of Contents
loading

Summary of Contents for Carrier Deluxe 58MVP

  • Page 1 Quality materials are the key behind the Infinity 96’s outstanding performance. Carrier stands behind quality. We offer lifetime warranty protection* on the heat exchangers, the heart of the Infinity 96. The rest of the unit is backed by a limited 5-year warranty.
  • Page 2 The Carrier Infinity convert furnace for use with propane Subsequent thermostat cycles provide System also provides unprecedented gas.
  • Page 3 A02287 NOTES: 1. The 58MVP Furnace is built for use with natural gas. The furnace can be converted for propane gas with a factory-authorized and listed accessory conversion kit. 2. Control location and actual controls may be different than shown above. Burner sight glass for viewing burner flame.
  • Page 4: Model Number Nomenclature

    060 — 60,000 Btuh 080 — 80,000 Btuh Media Filter Cabinet included 100 — 100,000 Btuh 120 — 120,000 Btuh Carrier accessories UNIT SIZE 040-14 060-14 080-14 080-20 100-20 120-20 2-in. — KGAVT0101BRA VENT TERMINATION KIT (Bracket Only for 2 Pipes) 3-in.
  • Page 5 Carrier accessories continued UNIT SIZE 040-14 060-14 080-14 080-20 100-20 120-20 ADVANCED PRODUCT MONITOR (software and hardware to link KGAFP0201APM pc laptop to control board) HK44EA120 ECM CONTROL REPLACEMENT MODULE - 1/2 HP HK52EA120 ECM CONTROL REPLACEMENT MODULE - 1 HP...
  • Page 6: Heat Exchangers

    One pipe runs inside the other a Carrier cased coil is used. It allowing venting through the is A.G.A. design certified for inner pipe and combustion air...
  • Page 7 Cleans the air of smoke, dirt, By adding moisture to winter- Available in programmable Carrier’s energy or heat and many pollens commonly dry air, a Carrier humidifier and non-programmable mod- recovery ventilators exhaust found. Saves decorating and can often improve comfort...
  • Page 8: Physical Data

    Physical data UNIT SIZE 040-14 060-14 080-14 080-20 100-20 120-20 OUTPUT CAPACITY BTUH* (ICS) Upflow 25,000 37,000 49,000 49,000 61,000 73,000 (Shaded capacities are Downflow 25,000 36,000 49,000 49,000 61,000 73,000 specified on rating plate) Horizontal 25,000 36,000 49,000 49,000 61,000 73,000 High...
  • Page 9 AIR DELIVERY - CFM (Bottom Return With Filter)* Unit Operating Mode CFM Airflow External Static External Static Pressure (ESP) Size Setting Pressure Range* AIRFLOW (CFM) †† Low Heat 585† 0-0.60 040-14 High Heat 0-1.0 †† 1-1/2-Ton Cooling 0-0.50 ‡ †† 2-Ton A/C Cooling 0-0.90 ‡...
  • Page 10 AIR DELIVERY - POWER DRAW (WATTS)** Unit Operating Mode CFM Airflow External Static External Static Pressure (ESP) Size Setting Pressure Range* POWER DRAW (WATTS)** 040-14 †† Low Heat 585 † 0-0.60 High Heat 0-1.0 †† 1-1/2-Ton Cooling 0-0.50 ‡ †† 2-Ton A/C Cooling 0-0.90 ‡...
  • Page 11: Condensate Trap

    Dimensions CONCENTRIC VENT B IN. DIA PVC VENT/EXHAUST C IN. DIA 1 /2 B IN. DIA PVC INTAKE/COMBUSTION AIR A97110 DIMENSIONS (in.) KIT PART NO. D† KGAVT0501CVT 33-3/8 3-1/2 16-5/8 6-1/4 5-3/4 KGAVT0601CVT 38-7/8 4-1/2 21-1/8 7-3/8 6-1/2 * Dimension A will change accordingly as dimension D is lengthened or shortened. †...
  • Page 13 DOWNFLOW SUBBASE DIMENSIONS (In.) FURNACE PLENUM OPENING* FLOOR OPENING HOLE NO. CASING FURNACE IN DOWNFLOW APPLICATION FOR WIDTH WIDTH ADJUSTMENT Furnace with or without CD5 or CK5 Coil 17-1/2 15-1/8 16-3/4 20-3/8 Assembly or KCAKC Coil Box Furnace with or without CD5 or CK5 Coil 18-5/8 20-1/4 20-3/8...
  • Page 14: Electrical Data

    Electrical data UNIT SIZE 040-14 060-14 080-14 080-20 100-20 120-20 UNIT VOLTS — HERTZ — PHASE 115 — 60 — 1 OPERATING VOLTAGE RANGE (Min — Max) 104 — 127 MAXIMUM UNIT AMPS 13.8 13.8 13.8 MINIMUM WIRE SIZE MAXIMUM WIRE LENGTH (Ft)‡ MAXIMUM FUSE OR CKT BKR (Amps) TRANSFORMER (24v) 40va...
  • Page 15: Combustion-Air And Vent Piping

    Combustion-air and vent piping MAXIMUM ALLOWABLE PIPE LENGTH (FT) ALTITUDE PIPE DIA NUMBER OF 90° ELBOWS ABOVE SEA UNIT SIZE TERMINATION TYPE (IN.)* LEVEL (FT) 1-1/2 040-14 2 Pipe or 2-In. Concentric 1-1/2 060-14 2 Pipe or 2-In. Concentric 1-1/2 080-14 2 Pipe or 2-In.
  • Page 16 MAXIMUM ALLOWABLE PIPE LENGTH (FT) Continued ALTITUDE NUMBER OF 90° ELBOWS ABOVE SEA PIPE DIA LEVEL (FT) UNIT SIZE TERMINATION TYPE (IN.)* 1-1/2 040-14 2 Pipe or 2-In. Concentric 1-1/2 060-14 2 Pipe or 2-In. Concentric 6001 to 7000‡ 1-1/2 080-14 2 Pipe or 2-In.
  • Page 17 MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT* INSULATION THICKNESS (IN.)† WINTER DESIGN MAX PIPE DIA UNIT SIZE TEMP °F (IN.) 040-14 - 20 060-14 - 20 080-14 080-20 - 20 2-1/2 100-20 2-1/2 - 20 2-1/2 120-20...
  • Page 18: Clearance To Combustibles

    Clearance to combustibles INSTALLATION This forced air furnace is equipped for use with natural gas at altitudes 0 - 10,000 ft (0 - 3,050m), except 140 size furnaces are only approved for altitudes 0 - 7,000 ft. (0 - 2,135m). An accessory kit, supplied by the manufacturer, shall be used to convert to propane gas use or may be required for some natural gas applications.
  • Page 19: Typical Installations

    Typical installations COMBUSTION AIR PIPE OUTDOOR UNIT VENT PIPE A/C COIL HUMIDIFIER GAS-FIRED ELECTRONIC WATER HEATER AIR CLEANER AIRFLOW Basement — Upflow Application A02307 ELECTRONIC AIR CLEANER VENT COMBUSTION HUMIDIFIER OUTDOOR UNIT A/C COIL AIRFLOW FRONT OF FURNACE Closet — Downflow Application A02308...
  • Page 20 FRONT OF DRAIN FURNACE Crawlspace — Horizontal Application A02310 • Copyright 2004 Carrier Corporation Indianapolis, IN 46231 09-04 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book Page 20 Catalog No.

This manual is also suitable for:

Infinity 96Infinity 96 58mvp

Table of Contents