Carrier Infinity 59MN7A Series 100 Product Data

Carrier Infinity 59MN7A Series 100 Product Data

Modulating 4-way multipoise condensing gas furnace

Advertisement

59MN7A
Infinityr Modulating
4---Way Multipoise
Condensing Gas Furnace
Series 100
The 59MN7A Multipoise Variable- -Capacity Condensing Gas
Furnace features the modulating InfinityR System. The innovative
modulating gas valve is at the heart of this furnace's quiet operation,
along with the variable- -speed Infinity ECM blower motor and
variable- -speed inducer motor. This furnace also provides 3.5 times
tighter temperature control than single stage furnaces. With an
Annual Fuel Utilization Efficiency (AFUE) up to 98.5%, this
Infinity gas furnace provides exceptional savings over standard
furnaces as well. This Infinity Gas Furnace also features 4- -way
multipoise installation flexibility. The 59MN7A can be vented as a
direct vent/two- -pipe furnace or as an optional ventilated
combustion air application. A Carrier InfinityR Control and an
Infinity Air Conditioner or Heat Pump can be used to form a
complete Infinity System. All units meet California Air Quality
Management District emission requirements. All sizes are design
certified in Canada.
STANDARD FEATURES
S Our quietest furnace. Compare for yourself at
HVACpartners.com.
S All sizes meet ENERGY STAR Version 4.0 criteria for gas
furnaces: 95+AFUE; AMACF electrical rating; 2% or less cabinet
airflow leakage.
S Supports single- - and multiple- -zone Infinity systems.
Product Data
S Ideal height 35" (889 mm) cabinet: short enough for taller coils,
but still allows enough room for service.
S Infinity Features—match with the Infinity Control for Infinity
System benefits
S Integral part of the Ideal Humidity SystemR Technology.
S Silicon Nitride Power Heat™ Hot Surface Igniter.
S SmartEvap™ technology helps control humidity levels in the
home when used with a compatible humidity control system.
S ComfortFan™ technology allows control of continuous fan speed
from a compatible thermostat.
S External Media Filter Cabinet included.
S 4- -way multipoise design for upflow, downflow or horizontal
installations, with unique vent elbow and optional through- -
the- -cabinet downflow venting capability.
S Variable- -Speed blower and inducer motors, modulating gas
A11263
valve.
S Self- -diagnostics and extended diagnostic data through the
Advanced Product Monitor (APM) accessory or Infinity User
Interface.
S Adjustable blower speed for cooling, continuous fan, and
dehumidification.
S Aluminized- -steel primary heat exchanger.
S Stainless- -steel condensing secondary heat exchanger.
S Propane convertible (See Accessory list).
S Factory- -configured ready for upflow applications.
S Fully- -insulated casing including blower section.
S Convenient Air Purifier and Humidifier connections.
S Direct- -vent/sealed combustion or ventilated combustion air
venting.
S Installation flexibility: sidewall or vertical vent.
S Residential installations may be eligible for consumer financing
through the Retail Credit Program.
S Certified to leak 2% or less of nominal air conditioning CFM
delivered when pressurized to 1- -in. water column with all present
air inlets, air outlets, and condensate drain port(s) sealed.
1
Use of the AHRI Certified
Mark indicates a
TM
manufacturer's participation in the program. For
verification of certification for individual products,
CERTIFIED
go to www.ahridirectory.org.
Always Ask For

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Infinity 59MN7A Series 100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Carrier Infinity 59MN7A Series 100

  • Page 1 S Propane convertible (See Accessory list). direct vent/two- -pipe furnace or as an optional ventilated combustion air application. A Carrier InfinityR Control and an S Factory- -configured ready for upflow applications. Infinity Air Conditioner or Heat Pump can be used to form a S Fully- -insulated casing including blower section.
  • Page 2: Features And Benefits

    When installed as a part of the system, this Ideal Humidity SystemR Technology — The Ideal Humidity cabinet allows for easy and convenient addition of a Carrier high system actively controls both temperature and humidity in the home efficiency air filter.
  • Page 3: Specifications

    SPECIFICATIONS Heating Capacity and Efficiency 060-14 060-20 080-14 080-20 100-22 120-22 Input Maximum Heat (BTUH) 60,000 60,600 80,000 80,000 100,000 120,000 Intermediate Heat (BTUH) 39,000 39,000 52,000 52,000 65,000 78,000 Minimum Heat (BTUH) 24,000 24,000 32,000 32,000 40,000 48,000 Output Maximum Heat (BTUH) 59,000...
  • Page 4: Model Number Nomenclature

    SPECIFICATIONS (CONTINUED) Controls 060-14 060-20 080-14 080-20 100-22 120-22 Limit Control Heating Blower Control (Heating Off-Delay) Adjustable: 90, 120, 150, 180 seconds Cooling Blower Control (Time Delay Relay) 90 seconds Communication System Infinity; Infinity Zoning Thermostat Connections R, W/W1, W2 Y/Y2, Y1, G, Com 24V, DHUM Accessory Connections EAC (115vac);...
  • Page 5 PGAPXX1625 Up to 1600 CFM Carrier Performance Air Purifier - 20x25 (508x635 mm) PGAPXX2025 Up to 2000 CFM Carrier Performance Air Purifier Repl Filter - 16x25 (406x635 mm) PGAPAXXCAR1625 GAPAAXCC1625 Carrier Performance Air Purifier Repl. Filter - 20x25 (508x635 PGAPAXXCAR2025...
  • Page 6 AIR DELIVERY - - CFM Cooling and Heating Air Delivery - - CFM (Bottom Return With Filter) (SW1-5 and SW4-3 set to OFF, except as indicated. See notes 1 and 2) Unit Size Clg/CF Switch Settings External Static Pressure (ESP) SWx-3 SWx-2 SWx-1...
  • Page 7 AIR DELIVERY - - CFM (CONTINUED) Cooling and Heating Air Delivery - - CFM (Bottom Return With Filter) (SW1-5 and SW4-3 set to OFF, except as indicated. See notes 1 and 2) Unit Size Clg/CF Switch Settings External Static Pressure (ESP) SWx-3 SWx-2 SWx-1...
  • Page 8 MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS INSULATION TABLE - - FT. / M Maximum Length of Uninsulated and Insulated Vent Pipe-Ft (M) No Insulation 3/8-in. (9.5 mm) 1/2-in. (12.7 mm) Modulating Pipe Pipe Diameter-inches (mm) Pipe Diameter-inches (mm) Pipe Diameter-inches (mm) Winter Design Furnace High Length in...
  • Page 9 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application. Table 1 –...
  • Page 10: Venting System Length Calculations

    Venting System Length Calculations The Total Equivalent Vent Length (TEVL) for EACH combustion air or vent pipe equals the length of the venting system, plus the equivalent length of elbows used in the venting system from Table 2. Standard vent terminations or factory accessory concentric vent terminations count for zero deduction. See vent system manufacturer’s data for equivalent lengths of flexible vent pipe or other termination systems.
  • Page 11 NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application. Table 3 – Maximum Equivalent Vent Length - - Ft. (M) 4501 to 10,000 Ft.
  • Page 12: Minimum Clearances To Combustible Materials

    RETURN AIR TEMPERATURE This furnace is designed for continuous return- -air minimum temperature of 60_F (15_C) db or intermittent operation down to 55_F (13_C) db such as when used with a night setback thermometer. Return- -air temperature must not exceed 80_F (27_C) db. Failure to follow these return air limits may affect reliability of heat exchangers, motors and controls.
  • Page 13 Carrier cased coil is used. It is combustion air to be drawn in through the outer pipe.
  • Page 14 MEDIA FILTER CABINET 25-5/8" (651mm) 24-1/4” 23-5/8" (616mm) (600mm) Opening with Flanges Bent 23-1/8” 23-3/8” (588mm) (594mm) Opening Duct Side Furnace Side 23-3/4” (603mm) " Centerline Screw Slots Media Filter (146mm) Cabinet 17" (432mm) 16" (406mm) 16" (406mm) 20" (508mm) 21"...
  • Page 15: Dimensional Drawing

    DIMENSIONAL DRAWING A12267 59MN7 SHIP WT. --- LB (KG) FURNACE SIZE CABINET WIDTH OUTLET WIDTH BOTTOM INLET WIDTH AIR INTAKE 060--- 14 154.0 (69.3) 17--- 1/2 (445) 15--- 7/8 (403) 16 (406) 8--- 3/4 (222) 080--- 14 164.0 (73.8) 060--- 20 158.5 (72.0) 080--- 20 21 (533)
  • Page 16 Draft inducer motor shall be variable- -speed design. Catalog No: 59MN7A ---04PD Copyright 2012 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Edition Date: 09/12 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

This manual is also suitable for:

59mn7a

Table of Contents