Carrier Infinity ICS 58MVC 100 Series Installation Instructions Manual page 13

Direct vent 4-way multipoise condensing gas furnace
Hide thumbs Also See for Infinity ICS 58MVC 100 Series:
Table of Contents

Advertisement

COMBUSTION
-
INTAKE
MAN1
SHUTOFF
GAS VALVE
(I46 mm)
A 12qN. (305 mm) MIN HORIZONTAL
PIPE
SECTION
IS RECOMMENDED
WITH
(5 TO 8 FT/1.5
TO 2.4 M) VENT
SYSTEMS
TO REDUCE
EXCESSIVE
CONDENSATE
DROPLETS
FROM
EXITING THE VENT PIPE.
30" (762 mm)MIN
)RK AREA
SEDIMENT
TRAP
CONDENSATE
TRAP
DRAIN
ACCESS OPENING
FOR TRAP
NOTE: LOCAL CODES MAY REQUIRE A DRAIN PAN UNDER THE
FURNACE AND CONDENSATE
TRAP WHEN A CONDENSING
FURNACE IS INSTALLED ABOVE FINISHED CEILINGS.
Fig. 12 - Attic Location
and Working
Platform
for Direct Vent
(2-Pipe)
Application
A93031
g
A 3-IN (76mm)
MINIMUM
CLEARANCE
TO COMBUSTION-AIR
INTAKE
IS REQUIRED.
COMBUSTI{
INTAKE
(146mm)
A 12-IN. (305mm)
MIN HORIZONTAL
PIPE
SECTION
IS RECOMMENDED
WITH
SHORT
(5 TO 8 FT / 1.5 TQ 2AM)
VENT
SYSTEMS
TO REDUCE
EXCESSIVE
CONDENSATE
DROPLETS
FROM
EXITING
THE VENT
PIPE.
30qN.
(762mm)
MIN
WORK AREA
MAN[
SHUTOFF
GAS VALVE
SEDIMENT
TRAP
CONDENSATE
TRAP
DRAIN
NOTE: LOCAL CODES MAY REQUIRE
A DRAIN PAN UNDER THE
FURNACE AND CONDENSATE
TRAP WHEN A CONDENSING
FURNACE
IS INSTALLED
ABOVE
FINISHED
CEILINGS.
Fig. 13 - Attic Location
and Working
Platform
for
Ventilated
Combustion
Air Applications
ACCESS
OPENING
FOR TRAP
A96184
13