Archgard 27-DVIM22 Users Installation Operation & Maintenance Manual

Archgard 27-DVIM22 Users Installation Operation & Maintenance Manual

Gas fired vented room heater (direct vent)

Advertisement

Quick Links

WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal
injury or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Gas Fired Vented Room
Heater (Direct Vent)
USERS' INSTALLATION
MAINTENANCE MANUAL
This appliance may be installed in an aftermarket
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by local
codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This appliance
is not convertible for use with other gases, unless a
certified kit is used.
7116 Beatty Dr
Mission, BC V2V 6B4
Canada
27-DVIM22
S/N 260000 And up
OPERATION and
*Conversion kit required for Propane use
Tested and
listed by
LABTEST Certification Inc
Richmond, British Columbia
ANSI Z21.88-2009/CSA 2.33-2009
200-1227
MAY 2014

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 27-DVIM22 and is the answer not in the manual?

Questions and answers

Summary of Contents for Archgard 27-DVIM22

  • Page 1 27-DVIM22 Gas Fired Vented Room Heater (Direct Vent) S/N 260000 And up USERS’ INSTALLATION OPERATION and MAINTENANCE MANUAL WARNING: If the information in this manual is This appliance may be installed in an aftermarket not followed exactly, a fire or explosion may...
  • Page 2 27-DVIM22...
  • Page 3 INTRODUCTION Congratulations on choosing an Archgard Gas Fireplace! The 27-DVIM22 is one of the most advanced Direct Vent Insert heaters available today. It is solidly designed using the latest technology and manufactured to the highest quality. It is our aim to provide you with an appliance for many trouble-free years of reliable service.
  • Page 4: Table Of Contents

    27-DVIM22 TABLE OF CONTENTS Caution and Safety Instructions Appliance Certification, Installation Codes and Specifications Rating Plate Configuring the Fireplace and Control Panel Locations Minimum Fireplace Opening Dimensions and Sealing the Vent Factory Built (metal) Fireplace Requirements 10-11 Mantle and Sidewall Clearance to Combustibles...
  • Page 5: Caution And Safety Instructions

    Y O U R S A F E T Y Do not install or operate your Archgard 27-DVIM22 without reading and understanding this manual. Any installation or operational deviation from this instruction manual voids the Archgard Industries Warranty and may prove hazardous.
  • Page 6: Appliance Certification, Installation Codes And Specifications

    The listing label is attached to the appliance on the bottom right side of the appliance. A copy is shown on page Please contact Archgard Industries Ltd., if you have any questions regarding the certification of this appliance. INSTALLATION CODES This appliance must be installed by a qualified gas appliance installer.
  • Page 7: Rating Plate

    27-DVIM22 RATING PLATE We recommend that our gas hearth products be installed and serviced by professionals who are certified in the U.S. by the National Fireplace Institute® (NFI) as NFI Gas Specialists.
  • Page 8: Configuring The Fireplace And Control Panel Locations

    27-DVIM22 CONFIGURE THE FIREPLACE - CONTROL PANEL LOCATIONS The control panels can be mounted in the following different ways. They are shipped in the “Controls In” configuration. They can be moved to the “Controls Out” configuration by removing the two mounting screw on each side and swinging the panels out and re- instaling the screws.
  • Page 9: Minimum Fireplace Opening Dimensions And Sealing The Vent

    27-DVIM22 MINIMUM FIREPLACE OPENING DIMENSIONS Masonry Fireplace Min flue size required TOP VIEW SIDE VIEW 4” (102) x 7” (178) Fig. 9-B Fig. 9-A DIMENSIONS 17-3/4” 15” 16” 25 1/2” 0” “Controls Out” (451 mm) (381 mm) (406 mm) (648 mm) DIMENSIONS 17-3/4”...
  • Page 10: Factory Built (Metal) Fireplace Requirements

    27-DVIM22 Factory –Built (metal) Wood-Burning Fireplace Opening Requirements Fig. 10-A I N S T A L L E R N O T E S The installer must mechanically attach a marking (supplied in the manual bag) to the inside of the firebox of the...
  • Page 11 27-DVIM22 W A R N I N G Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. W A R N I N G Any hearth extending out in front of the insert must not have any portion above 7”...
  • Page 12: Mantle And Sidewall Clearance To Combustibles

    27-DVIM22 MANTLE CLEARANCES W A R N I N G Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. Fig. 12-A...
  • Page 13: Gas Connections

    27-DVIM22 GAS CONNECTIONS Before connecting the appliance to the gas supply line, double check that the appliance you have purchased is designed for the gas type you are using. The gas type markings are located on the certification label and also on the appliance’s gas valve.
  • Page 14: Conversion Kit Instructions

    27-DVIM22 CONVERSION KIT INSTRUCTIONS W A R N I N G The conversion kit shall be installed by a qualified service agency in accordance with the manufacturers instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explo- sion or productions of carbon monoxide may result, causing property damage, personal injury or loss of life.
  • Page 15 Ensure that the rubber gasket is properly positioned and install the new modulating pressure regulator assembly to the valve using the screws provided in the conversion package. Affix Archgard Manufacturer’s label (part # 303-0128) in a conspicuous location. We suggest a location close to the gas control valve.
  • Page 16: Appliance Description, Leveling The Appliance And Electrical Requirements

    “L” bracket at the back of the appliance. Lower it to the measurement obtained and tighten the screws. ELECTRICAL CONNECTIONS The 27-DVIM22 comes complete with an thermally controlled variable speed fan equipped with a solid state speed control. Do not cut or remove the grounding prong from this plug.
  • Page 17: Venting Instructions

    3” (76 mm) inside bend radius. The Air Intake Flex Liner must be connected to the inlet The 27-DVIM22 showing the Fresh Air Intake and air collars of the termination cap and the appliance. Exhaust locations. These connections are labeled.
  • Page 18 27-DVIM22 VENTING INSTRUCTIONS 999-INS-TK Instructions for use with Archgard vertical termination cap. Part # 999-INS-TK Install the termination cap being sure to provide sufficient space (around and on top) so as not to impede the flow of air, both into and out of the cap. This cap is only to be used for non combustible installations. Do not recess into the top of the chim- ney.
  • Page 19: Optional Wall Switch/Thermostat And Fan Wiring Diagrams

    If a wall mounted switch or a wall mounted thermostat is desired, Archgard recommends that the device be wired as shown in the diagram below. NOTE: Archgard Industries does not manufacture or sell any type of wall switch or wall thermostat and will not extend warranty to them...
  • Page 20: Surround Installation And Rocker Switch Wiring

    27-DVIM22 SURROUND INSTALLATION Surround options available are dependent upon the control panel configuration. (See Control Panel Locations regarding configuration.) Shallow surround options are not available on a unit with ‘Controls Out’ configuration. Make sure the gas and electrical lines are properly connected to the appliance. Slide the unit into the fireplace and slide the excess flue liner material back onto the chimney.
  • Page 21: Log Placement

    27-DVIM22 LOG PLACEMENT The Archgard pan burner bed and fiber logs are designed to give a realistic fire package, and created to look the same as the day they were originally installed. Care must be given when first installing the logs, and if removed for servicing, as they can be damaged or broken if not handled properly.
  • Page 22 27-DVIM22 LOG PLACEMENT... Continued L O G Locate Log 1 and align the holes in the bottom line up with the two locater pins. Push down firmly onto locater pins. Fig. 22-A LOG #1 L O G # 2 Locate log #2 using the locator pin on the burner for the left side. Sit the right side of the log into the...
  • Page 23 27-DVIM22 LOG PLACEMENT... Continued L O G Locate Log #4 and align the two holes in the log with the two locater pins in the center of the burner. Push down onto locator pins as shown. Fig. 23-A LOG #4 L O G Locate Log #5 and align the hole in the bottom with the locater pin in the burner.
  • Page 24 27-DVIM22 LOG PLACEMENT... Continued N O T E Logs #1, #3 and #4 have been crafted to allow airflow from under the logs. DO NOT crush the bottom of the logs to make these sit flush with the top of the burner. Care must also be taken to not completely block the front of the logs with embers.
  • Page 25 27-DVIM22 COMPLETE LOG SET Fig. 25-A LOG 5 LOG 2 LOG 1 LOG 3 LOG 6 LOG 4 Item # Item Description Unit 310-6270 Complete Log Set 310-6270-1 Log 1 (Right Side) 310-6270-2 Log 2 (Rear) 310-6270-3 Log 3 Left Side)
  • Page 26: Glass Door Removal / If Your Glass Should Break

    Do not operate appliance with the glass front cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. IF YOUR GLASS BREAKS In the event your glass cracks or breaks, Archgard recommends that a complete new door assembly be ordered to replace the original door. ...
  • Page 27: Final Installation Check And Initial Operation

    27-DVIM22 FINAL INSTALLATION CHECK Each Archgard Gas Fireplace is checked and tested at the factory prior to being packaged and shipped to our dealers and finally installed in your home. Archgard recommends that before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and that the electrical system is in working order.
  • Page 28: First Fire And Lighting Instructions (Caution)

    27-DVIM22 FIRST FIRE A T T E N T I O N When operated for the first few times, the appliance will emit some odor and fumes. This is due to the heat evaporating the oils and solvents used in the production of the fireplace.
  • Page 29: Lighting Instructions On Rating Plate

    27-DVIM22 LIGHTING INSTRUCTIONS ON RATING PLATE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire of explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by a spark ignitor.
  • Page 30: Maintenance And Cleaning The Appliance

    Regularly:  Frequent cleaning of the ceramic glass is required. Archgard recommends using a good quality “gas fireplace” glass cleaner that is available at any hearth retail location. DO NOT CLEAN WHILE HOT.
  • Page 31: Servicing Under Warranty And Adjusting Primary Air

    27-DVIM22 SERVICING UNDER WARRANTY Before servicing, read the terms and conditions of the Archgard warranty at the back of the manual. Contact the authorized Archgard dealer where you purchased the appliance from and provide them with details of the problem, along with the initial installation information (from the front of this manual).
  • Page 32: Checking Inlet/Outlet Gas Pressures, Adjusting Pilot And Convertible Pilot Orifice

    7/16” (11 mm) wrench turn a 1/4 open then push the small metal tab across to the other side of the body and retighten. Call your local Authorized Archgard Dealer to pur- 7/16” (11 mm) chase the correct fuel conversion kit for...
  • Page 33: Replacing Convection Blower

    27-DVIM22 REPLACING COMFORT BLOWER C A U T I O N Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code, CSA C22.1.
  • Page 34: Troubleshooting

    27-DVIM22 TROUBLESHOOTING Please check to make sure the instructions are followed exactly before attempting troubleshooting of the appliance. W A R N I N G Troubleshooting and servicing of gas and electrical devices of the appliance should only be conducted by a qualified service technician.
  • Page 35 27-DVIM22 TROUBLESHOOTING Cont... SYMPTOM ACTION The main burner does not turn 3. Check to make sure the thermostat is set high enough to turn on the on with the pilot lit. Cont... appliance. 4. Check that the remote switch or the thermostat is turned on.
  • Page 36: Warranty

    Problem Description ❖ NOTE: Warranty may be void if work is carried out by an unqualified person (s). Only original Archgard parts may be used. Please consult your Archgard dealer or representative if in doubt about a replacement part (s).
  • Page 37: Frequently Asked Questions

    Q. My fan/blower makes a “whirring” or “humming” noise. A. Your Archgard gas appliance uses a powerful fan to push heated air into your room. It is not un- usual to hear a “humming” noise when your fan is running. Note: the sound will change depending on the setting that your fan speed control is set at.
  • Page 38: Replacement Parts

    27-DVIM22 REPLACEMENT PARTS LIST - ARCHGARD 27-DVIM22 Item # Item Description Unit 308-0013 Valve, SIT 820 Nova, Hi/Low Natural Gas 308-0008 Piezo Igniter (Sparker) 301-0068 Orifice (Main Burner Orifice) Drill to # 43 DMS for Natural Gas Orifice (Main Burner Orifice) Drill to # 54 for LP (Propane) Gas...
  • Page 39: Warranty Registration Card

    POSTAGE WARRANTY REGISTRATION RCHGARD NDUSTRIES 7116 BEATTY DRIVE MISSION, B.C. CANADA V2V 6B4 FOLD DOWN AT LINE FOLD DOWN AT LINE & TAPE CLOSED 27-DVIM22 Model # : Serial #: Date Installed: yyyy Name: Address: City: State/Prov: ZIP: Phone: ( _____ ) Dealer's Name &...
  • Page 40 Archgard Industries Ltd. 7116 Beatty Drive Mission, B.C. V2V 6B4 Canada Website: www.archgard.com...

Table of Contents