f i r e - p a r t s . c o m
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS:
 Do not try to light any appliance
 Open windows
 Do not touch any electrical switch; do not use any
phone in your building
 Extinguish any open flame
 Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions
 If you cannot reach your gas supplier, call the fire
department.
 Do not use this appliance if any part has been under
water. Immediately call a qualified service techni-
cian to inspect the appliance and to replace any part
of the control system and any control that has been
under water.
Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
INSTALLER: Please leave this manual with the appliance owner for future reference.
Vented Gas Fireplace Insert
U
SERS'
O
PERATION AND
M
AINTENANCE
*Conversion Kit Required for Propane Use
7116 Beatty Drive
Mission, BC V2V 6B4
Canada
EURO 25
EURO 25
25
-
BVI20N
25
-
BVI20N
Heating Appliance
SN 13066 AND UP
I
NSTALLATION
NOT FOR USE WITH SOLID FUEL
WARNING: If the information in this manual
is not followed exactly, fire or explosion may
result causing property damage, personal
injury or loss of life.
-
2
-
2
M
ANUAL
200-0215
November 2010

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 25-BVI20N-2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Archgard 25-BVI20N-2

  • Page 1 EURO 25 EURO 25 BVI20N BVI20N Vented Gas Fireplace Insert Heating Appliance SN 13066 AND UP SERS’ NSTALLATION PERATION AND AINTENANCE ANUAL f i r e - p a r t s . c o m Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2 STATE OF MASSACHUSETTS REQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
  • Page 3 INTRODUCTION Congratulations on purchasing the Archgard Euro-25 Gas Fireplace Insert Heater! The Euro-25 is one of the most advanced gas heating appliances on the market. It is designed using the latest technology and manufactured to the highest quality. Some of the many features of the Euro 25 are:...
  • Page 4: Table Of Contents

    TABLE OF CONTENTS Page Caution & Safety Information General Information Appliance Description and Dimensions Installation Instructions Log Placement Operation Instructions Maintenance Troubleshooting Instructions f i r e - p a r t s . c o m Servicing APPENDIX A - Installation Into Vented Gas Fireplaces Suitable Host Fireplaces / Specific Installation Instructions Important Information Form Warranty...
  • Page 5: Caution & Safety Information

    SAFETY FOR YOUR SAFETY - Do not install or operate your Archgard Euro 25 Gas Fireplace Insert Heater without reading and understanding this manual. Any installation or operational deviation from this instruction manual voids the Archgard Industries Ltd.
  • Page 6: General Information

    This appliance is tested and certified to the following U.S. and Canadian gas appliance standards. - ANSI Z 21.88b-2003 / CSA 2.33b-2003, Vented Gas Fireplace Heater - CAN/CGA-2.17-M91, Gas-Fired Appliances for Use at High Altitudes. Please contact Archgard Industries Ltd., if you have any questions regarding the certification of these appliances. INSTALLATION CODES This appliance must be installed by a qualified gas appliance installer.
  • Page 7: Appliance Description And Dimensions

    25-BVI20N –2 APPLIANCE DESCRIPTION & DIMENSIONS FRONT VIEW SURROUND TOP LOUVERS BAY GLASS DOOR CONVECTION FAN SPEED CONTROL GAS VALVE f i r e - p a r t s . c o m SPARKER REMOVABLE CONTROL COVER APPLIANCE DIMENSIONS 30 ¼”...
  • Page 8: Installation Instructions

    CAUTION: This appliance is designed for use in any masonry, factory-built wood burning and specific zero-clearance vented gas fireplaces (Due to constant additions, contact Archgard Industries for an updated list of suitable gas fireplaces). This appliance cannot be enclosed with...
  • Page 9 25-BVI20N –2 INSTALLATION INSTRUCTIONS - Continued MINIMUM MASONRY FIREPLACE DIMENSIONS SIDE VIEW TOP VIEW 12” (305 mm) 19 ½” (495 mm) 17” (432 mm) 25” (635 mm) f i r e - p a r t s . c o m The standard flue adapter will fit if is more than 5 ¾”.
  • Page 10 25-BVI20N –2 INSTALLATION INSTRUCTIONS - Continued MINIMUM ZERO-CLEARANCE WOOD BURNING FIREPLACE DIMENSIONS SIDE VIEW TOP VIEW 12” (305 mm) 15 ¼” (387 mm) 17” (432 mm) 25” (635 mm) f i r e - p a r t s . c o m The standard flue adapter will fit if is more than 5 ¾”.
  • Page 11 25-BVI20N –2 INSTALLATION INSTRUCTIONS - Continued To install the Euro 25 into a vented gas fireplace, see APPENDIX A (page 24) for installation instructions. PRECAUTIONS  This appliance must be installed by a qualified gas installer and the installation must conform to the installation codes.
  • Page 12: Gas Connections

    25-BVI20N –2 INSTALLATION INSTRUCTIONS - Continued VENTING - Continued Caution: Make sure the flue adapter plate is not too far back, or the appliance will not vent properly. X = ¼” minimum The arms can also be bent up and out of the way if the adapter plate is forward enough to interfere with the surround.
  • Page 13 25-BVI20N –2 INSTALLATION INSTRUCTIONS - Continued ATTACHMENT OF FIREPLACE SURROUND 3 - THE SPILL SWITCH IS CONNECTED TO THE APPLIANCE (FACTORY- WIRED) 1) The surround has four hooks that clip onto the sides of the appliance. Make sure the surround sits evenly with the front of the fireplace. After the surround is properly installed, the f i r e - p a r t s .
  • Page 14 25-BVI20N –2 INSTALLATION INSTRUCTIONS - Continued GLASS DOOR WARNING: Glass door is fragile. Do not strike or abuse glass. Do not operate appliance with broken glass. Do not attempt to fix a broken glass door. It must be replaced with an identical one from the manufacturer.
  • Page 15: Log Placement

    25-BVI20N –2 LOG PLACEMENT The following pages outline the steps for correctly placing the logs and platinum embers in your Euro 25-1. Upon completion, the logs and embers should look as shown in the photo below. f i r e - p a r t s . c o m WARNING: Do not place the logs or branches in any configuration other than the one shown.
  • Page 16 25-BVI20N –2 LOG PLACEMENT - Continued STEP 1 - Locate log #1 and place onto rear log support using locator pins and pre-drilled holes in log. Log will sit as shown in the photo below. f i r e - p a r t s . c o m STEP 2 - Locate log #2 and place onto the left side of the burner using locator pins and pre-drilled holes in log.
  • Page 17 25-BVI20N –2 LOG PLACEMENT - Continued STEP 3 - Locate log #3 and place onto centre of burner using the locator pins and pre-drilled holes in log. Log should sit as shown in photo below. f i r e - p a r t s . c o m STEP 4 - Locate log #4 and place onto right side of burner using the locator pins and pre-drilled holes in log.
  • Page 18 25-BVI20N –2 LOG PLACEMENT - Continued STEP 5 - Locate log #5 and place onto rear log using the locator pins and pre-drilled holes in log. Log should sit as shown in photo below. f i r e - p a r t s . c o m STEP 6 - Locate log #6 and place onto rear log using the locator pins and pre-drilled holes in log.
  • Page 19 25-BVI20N –2 LOG PLACEMENT - Continued STEP 7 - Locate log #7 and place onto rear log using the locator pins and pre-drilled holes in log. Log should sit behind left grate tine as shown in photo below. f i r e - p a r t s . c o m FINAL LOG PLACEMENT - Please note that all logs should be placed exactly as shown.
  • Page 20: Operation Instructions

    25-BVI20N –2 OPERATION INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING INITIAL OPERATION Check that the appliance is properly vented and connected to the gas supply.  Check that the logs and branches are properly placed.  Check all external parts, such as grills, door and control cover are properly attached and ...
  • Page 21 25-BVI20N –2 OPERATION INSTRUCTIONS - Continued START-UP PROCEDURE Set the thermostat, if present, to the lowest level. Set the flame adjustment knob to the HI  position. Press slightly and turn the control knob clockwise to the OFF position and wait 5 minutes;...
  • Page 22: Maintenance

    25-BVI20N –2 MAINTENANCE CAUTION : Maintenance should only be conducted on a cold appliance. CLEANING THE APPLIANCE The exterior painted surfaces, glass and gold trims may be cleaned with a soft, non-abrasive cloth and water or a suitable, mild, non-abrasive cleaner. Regularly: Clean and remove any lint accumulations or debris from the grills and in any ...
  • Page 23: Troubleshooting Instructions

    25-BVI20N –2 TROUBLESHOOTING Please check to make sure the instructions are followed exactly before attempting troubleshooting of the appliance. WARNING: Troubleshooting and servicing of gas and electrical devices of the appliance should only be conducted by a qualified service technician. SYMPTOM ACTION Pilot will not light after pressing the...
  • Page 24 25-BVI20N –2 TROUBLESHOOTING - Continued SYMPTOM ACTION The main burner does not turn on with 3. If using an optional thermostat, check to make sure the thermostat is set high enough the pilot lit. (continued) to turn on the appliance. 4.
  • Page 25: Servicing

    SERVICING SERVICING UNDER WARRANTY Before servicing, read the terms and conditions of the Archgard warranty at the back of the manual. Contact the Archgard authorized dealer from which you have purchased the appliance and provide him with details of the problem and the installation information which the installer has filled out at the back of this manual.
  • Page 26 25-BVI20N –2 SERVICING - Continued REPLACEMENT OF FAN Disconnect the power to the appliance.  Remove the louvers, control cover door, brick panels, logs and burner.  Remove the firebox lower back. Remove the screws located at the back of the firebox. Take the ...
  • Page 27 7/16” (11 mm) wrench turn a ¼ open then push the small metal tab across to the other side of the body and retighten. Call your local Authorized Archgard Dealer to purchase the correct fuel conversion kit for your gas appliance.
  • Page 28: Appendix A - Installation Into Vented Gas Fireplaces

    This installation must be conducted by a qualified gas appliance installer and  the installation must conform to the installation codes. This EURO 25 gas insert will only fit into the gas fireplaces on Archgard’s list  of suitable gas fireplaces. Each of these fireplaces have been tested and approved for use with the EURO 25.
  • Page 29  Remove the burner or sandpan, pilot, and all parts of the gas train assembly.  Attach the Archgard modification warning plate (see sample, page 26) to the  host fireplace label. Attach the warning label (see sample, page 26) provided with the EURO 25 ...
  • Page 30 25-BVI20N –2 APPENDIX A EURO 25 - INSTRUCTIONS FOR INSTALLATION INTO VENTED GAS FIREPLACES VENTING OF THE EURO-25 INSIDE THE HOST GAS FIREPLACE A connector kit (25-ICKIT4 or 25-ICKIT5) is used to connect the EURO 25 insert to the host gas fireplace’s venting system. The connector slips into the host fireplace’s B-vent.
  • Page 31 SAMPLE MODIFICATION WARNING PLATE WARNING : This fireplace has been modified for use with the Archgard EURO-25 gas insert. Usage f i r e - p a r t s . c o m without the EURO-25 gas insert may cause property damage, personal injury or loss of life.
  • Page 32: Suitable Host Fireplaces / Specific Installation Instructions

    All installation requirements in the manual must also be carefully observed and followed. 7. Use Archgard 25-ICKIT5 connector kit to connect the insert to the host’s B-vent or connect a 4” diameter flexible aluminum gas vent from the insert to the host’s vent cap.
  • Page 33 - p a r t s . c o m carefully observed and followed. 6. Use Archgard 25-ICKIT5 connector kit to connect the insert to the host’s B-vent or connect a 4” diameter flexible aluminum gas vent from the insert to the host’s vent cap.
  • Page 34 All installation requirements in the manual must also be carefully observed and followed. 8. Use Archgard 25-ICKIT5 connector kit to connect the insert to the host’s B-vent or connect a 4” diameter flexible aluminum gas vent from the insert to the host’s vent cap.
  • Page 35 All installation requirements in the manual must also be carefully observed and followed. 8. Use Archgard 25-ICKIT5 connector kit to connect the insert to the host’s B-vent or connect a 4” diameter flexible aluminum gas vent from the insert to the host’s vent cap.
  • Page 36 - p a r t s . c o m carefully observed and followed. 8. Use Archgard 25-ICKIT5 connector kit to connect the insert to the host’s B-vent or connect a 4” diameter flexible aluminum gas vent from the insert to the host’s vent cap.
  • Page 37: Important Information Form

    25-BVI20N –2 IMPORTANT INFORMATION * Please have the installer fill out the installation information for warranty and future reference. APPLIANCE MODEL NUMBER 25-BVI20N-2 SERIAL NUMBER GAS TYPE • NATURAL GAS • LPG VALVE TYPE Robertshaw 7000MVRB DATE PURCHASED OWNER NAME...
  • Page 38: Warranty

    Problem Description ❖ NOTE: Warranty may be void if work is carried out by an unqualified person (s). Only original Archgard parts may be used. Please consult your Archgard dealer or representative if in doubt about a replacement part (s).
  • Page 39: Replacement Parts

    25-BVI20N –2 REPLACEMENT PARTS FOR 25-BVI20N-2 ITEM # DESCRIPTION QTY. UNIT 200-0215 OWNER’S MANUAL 301-0068 ORIFICE, CAP #45 (NATURAL GAS) 301-0060 ORIFICE, CAP #55 (PROPANE) 305-0013 SPEED CONTROL, c/w PALE NUT & KNOB, 120V 305-0019 ROCKER SWITCH, CARLING RA911-VB-B-1VXAG1 305-0021 THERMODISC, 110°F, FAN SWITCH...
  • Page 40: Notes

    25-BVI20N –2 NOTES f i r e - p a r t s . c o m...
  • Page 41: Warranty Registration Card

    MISSION, B.C. CANADA V2V 6B4 FOLD DOWN AT LINE f i r e - p a r t s . c o m FOLD DOWN AT LINE & TAPE CLOSED Model # : 25-BVI20N-2 Serial #: Date Installed: yyyy Name: Address:...
  • Page 42 f i r e - p a r t s . c o m...
  • Page 43 Archgard Industries Ltd. 7116 Beatty Drive f i r e - p a r t s . c o m Mission, B.C. V2V 6B4 Canada Website: www.archgard.com...

Table of Contents