40-6520_6530
5 and 6. Up/Down button
In continuous scan mode
• Press to increase scan speed
• Press to decease scan speed
In range scan mode
• Press to make the scanned range rotate clockwise
• Press to make the scanned range rotate counterclockwise
Usage for horizontal output status
• Reference "Instrument Usage" previously discussed
Usage for vertical output status
IMPORTANT: Keep "Locking Knob" in the "Locked" position.
1. Install batteries/battery pack as previously discussed.
2. Insert the "Adjusting knob" and place the instrument horizontally
on a stable platform (see fig. 5) or mount it on the tripod with
vertical mount.
3. Turn the "Adjusting Knob" until the bubble is centered.
4. Power on and select
the work state that you
need by pressing the
mode button on the
operating panel.
5. Power the instrument off
when you finish work or
make any movement.
10
4/20/05
4:12 PM
Leveling Vial
Adjusting
Knob
Page 10
©2005 Johnson Level & Tool
Handle
Vertical
Mount