The stove is delivered ready for top outlet, but may be changed to back outlet in the fol-
lowing way:
RAIS - Manual for RAIS RIVA
Loosen the 3 pcs. M6 nuts by a wrench.
Mount the smoke discharge socket, which is found in
a bag in the stove, and the clamp for the upper smoke
conductor with three M6x20 cylinder screws and M6
nuts.
Mount the upper smoke conductor, smoke converter
plate and top plate in reverse order.
Remove smoke converter
plate and smoke conduc-
tor (see cleaning and care).
Remove the blank flange
and the packing, and posi-
tion them in the hole at the
top. See to it that the pack-
ing is positioned correctly.
Screw all elements together
with the three M6 nuts.
11