Component Specification - Viking VCBB360R Service Manual

Table of Contents

Advertisement

Component Specifications
Component
Description
Bulb
Capacitor, compressor run
Compressor Type
Drier
Heater, evaporator
Heater, Mullion
For service use only,
foamed in place. Not
powered from the
factory.
High voltage circuit board P.C.
Low voltage circuit board
Test Procedures
Volts
Watts
Volts
Capacitance
BTUH
Volts
Watt
Current: Lock rotor
Full load
Resistance: Run windings 2.60Ω
Start windings 4.35Ω
Drier must be changed every time the system is opened
for testing or compressor replacement.
Desiccant
(20) 8x12.4AXH – 7 M. S.-Grams
Volt
Wattage
Resistance
Volt
Wattage
Resistance
To connect mullion heater to power:
1. Disconnect power to unit using power switch.
2 Remove toe grille. Locate water valve wiring harness.
3 Carefully, slit wiring harness vinyl sleeve to expose one
black and one white lead bent with bullet terminators.
4, Locate mullion heater leads at the left side of cabinet and
connect to black and white leads.
5. Wrap vinyl sleeve with electrical tape to close slit.
See "Electronic Functional Description".
See "Electronic Functional Testing".
20
120VAC
40 watts
220VAC
15 µfc + 10%
- 5%
Fan cooled, R134a refrigerant
970 BTUH
120VAC 60Hz
176 watts
21.3 A
!.6 A
120VAC
450 ±5% W
30 ± 5% Ω
120VAC
20Watts
661 ± 7.5Ω