Shark SSG-503027E Operator's Manual page 16

Hide thumbs Also See for SSG-503027E:
Table of Contents

Advertisement

PROBLEM
BURNER WILL NOT
LIGHT
(continued from
previous page)
FLUCTUATING
PRESSURE
MACHINE SMOKES
16
TROUBLESHOOTING
POSSIBLE CAUSE
Flex coupling slipping on fuel pump
shaft or burner motor shaft
On-Off switch defective
Heavy sooting on coil and burner can
cause interruption of air flow and
shorting of electrodes
Improper electrode setting
Fuel not reaching combustion
chamber
Clogged burner nozzle
Thermostat faulty or slow engine
speed
Flow switch malfunction
Flow solenoid malfunction
Valves worn
Blockage in valve
Pump sucking air
Worn piston packing
Improper fuel or water in fuel
Improper air adjustment
Low fuel pressure
Plugged or dirty burner nozzle
Faulty burner nozzle spray pattern
Heavy accumulation of soot on coils
and burner assembly
Misaligned electrode setting
Obstruction in smoke stack
Low engine RPM
97-6142, 97-6134 • REV. 9/04
SOLUTION
Replace if needed.
Check for electrical current reaching burner
assembly with burner switch on.
Clean as required.
Check and reset according to diagram in
Operator's Manual.
Check fuel pump for proper flow. Check
solenoid flow switch on machines with spray
gun control, for proper on-off fuel flow
control.
Clean as required.
Increase engine RPM to increase voltage.
Remove, test for continuity and replace as
needed.
Replace if needed.
Check and replace if necessary.
Check and replace if necessary.
Check water supply and air seepage at joints
in suction line.
Check and replace if necessary.
Drain tank and replace contaminated fuel.
Readjust air bands on burner assembly.
Adjust fuel pump pressure to specifications.
Replace nozzle.
Replace nozzle.
Remove coils and burner assembly, clean
thoroughly.
Realign electrodes to specifications.
Check for insulation blockage or other foreign
objects.
Increase RPM.

Advertisement

Table of Contents
loading

Table of Contents