2. Use the [] and [] keys to select the area that you
want to program the entry time for, then press
[OK] to select. Alternatively, you can enter the area
number that you want to program, then press [OK].
The keypad will display the following:
Entry Time 2 A1
Reception Area
040 Seconds
Press 0-9 OK to SAVE
3. Use the numeric keys to enter the required time in
seconds and then press [OK]. Entry time 1 can be set
from 0 to 255 seconds.
Areas > Timers >

Part Entry Time

This menu allows the master user to modify the part mode
entry timer for the selected area. Each area in the system
can have a different part entry time if required.
installer may have set up one or more part modes on your
system during installation.
When the system is armed in part mode, some zones will be
turned off allowing you to move around in certain rooms in
the building while zones in the rest of the building are fully
armed.
The part entry timer will begin counting down whenever
an armed zone is triggered. The keypad will sound an
entry warning beep during this time to let you and other
users know that the area needs to be disarmed.
If the area is not disarmed before the part mode entry time
expires then an alarm will occur.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [2] + [8] + [3].
A list of available areas will display on the keypad.
A1 Reception Area
A2 Sales Dept
A3 Administration Dept
Press

2. Use the [] and [] keys to select the area that you
want to program the entry time for, then press
[OK] to select. Alternatively, you can enter the area
number that you want to program, then press [OK].
The keypad will display the following:
Part Entry Time A1
Reception Area
060 Seconds
Press 0-9 OK to SAVE
3. Use the numeric keys to enter the required time in
seconds and then press [OK]. Entry time 1 can be set
from 0 to 255 seconds.
Bosch Security Systems 04/12 BLCC600U
MENU 2-8-3
OK or MENU

Inputs

Each panel can have up to a maximum 144 zones. When
the optional radio receiver is fitted any available zone
may be programmed as a wireless zone. Your installer will
advise you on the exact makeup and configuration of your
system.
Inputs > Commands >

Zone Status

This menu allows you to view the zone status of each zone
(i.e. Normal, Open or Short).
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [3] + [0] + [0].
A list of different zones will display on the keypad.
2. Use the [] and [] keys to select the zone that you
want to turn view the status information then press
[OK] to select. Alternatively, you can enter the zone
number that you want to view status information,
Your
then press [OK].
The keypad will display the following zone status
information:
Zone 1 Name Zn1
EOL=Normal 06523 ohms
Press OK or MENU
3. Press the [OK] key to exit.
Inputs > Commands >

Bypass Zones

This menu allows you to bypass or un-bypass a single or
multiple zones before you turn the area All On, Part On or
Part 2 On. When bypassing zones, it disables the ability for
a zone to detect intrusion and sound an alarm.
A burglary zone will automatically become un-bypassed
when you turn the corresponding area off (disarm). Any
24-Hr fire or 24-Hr non fire zones will need to be manually
un-bypassed.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [3] + [0] + [2].
A list of zones that can be bypassed will display
on the keypad. A '√' displayed on the right side of
the zone name indicates that the zone is already
bypassed.
Zn1 Zone 1 Name 
Zn2 Zone 2 Name
Zn3 Zone 3 Name
Press
Solution 144
OK or MENU

User Guide
MENU 3-0-0
MENU 3-0-2
21