Unit Does Not Open /Close Properly (Procedure 21) - Vadem Clio Service Manual

Clio vadem
Table of Contents

Advertisement

CLIO Service Manual
4.21.
U
D
NIT
OES
Ensure Battery Cover is
properly secured to the unit.
Fixed?
N
Check for visible external
damage.
Damage?
N
Check function of bottom
hinge
Satisfactory?
Y
Check function of top hinge
Satisfactory?
Y
Remove Lower Arms to
ensure Display Connection
FCP is not binding
Satisfactory?
Y
Ensure backlight wires are
not binding
Satisfactory?
Y
The information contained in this document is confidential and the sole property of Vadem Inc. Written
permission must be obtained to reprint or use any of this information.
AUTHORED BY ANTHONY HERNANDEZ - (415)786-2081 - anthonyh@ashlandhome.net
N
O
/C
OT
PEN
LOSE
Y
Y
Replace parts as appropriate
N
Replace lower hinge
N
Replace upper hinge
Reroute or replace Display
N
Connection FCP as
appropriate
N
Reroute or replace backlight
wires as appropriate
4-21
P
(P
ROPERLY
Replace Metal Arm
Go to Final Test
Procedure
N
Fixed?
Y
Y
Fixed?
N
Y
Fixed?
N
Y
Fixed?
N
Y
Fixed?
N
CLIO Diagnostics
21)
ROCEDURE

Advertisement

Table of Contents