Fire Hazard
Use a heavy metam vent.
De net use a pBaetic vent,
De net use a metam foil vent,
Failure to fellow
these instructions
can result in death
or fire,
WARNING:
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances,
The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, or a concealed space of a building,
If using an existing vent system
Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint.
Replace any plastic or metal foil vent with rigid or flexible
heavy metal vent.
Review Vent system chart. Modify existing vent system if
necessary to achieve the best drying performance.
If this is a new vent system
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.
4" (10.2 cm) heavy metal exhaust vent and clamps must be
used. DURASAFE
TM
venting products are recommended.
4" (!0.2 cm) heavymetal exhaust vent
DURASAFE
TM
vent products can be purchased from your
dealer. For further information, please call
®
1-800-4-MY-HOME
(1-800-469-4663)
or visit our website at
www.sears.com.
Rigid metal vent
For best drying performance,
rigid metal vents are
recommended.
Rigid metal vent is recommended
to avoid crushing and
kinking.
Flexible metal vent
Flexible metal vents are acceptable only if accessible for
cleaning.
Flexible metal vent must be fully extended and supported
when the dryer is in its final position.
Remove excess flexible metal vent to avoid sagging and
kinking that may result in reduced airflow and poor
performance.
Do not install flexible metal vent in enclosed walls, ceilings or
floors.
Elbows
45 ° elbows provide better airflow than 90 ° elbows.
Good
Better
Clamps
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into the interior of the
duct. Do not use duct tape.
!Oc
Clamp
Exhaust
Recommended
hood styles are shown here.
B
(10.2cm)
A. Louvered hood style
B. Box hood style
14