B I O S s e t u p a n d m e n u s
Error Message
Fixed Disk 0 Failure or Fixed Disk 1
Failure or Fixed Disk Controller
Failure
Incorrect Drive A type - run SETUP
Invalid NVRAM media type
Keyboard controller error
Keyboard error
Keyboard error nn
Keyboard locked - Unlock key switch
Monitor type does not match CMOS
- Run SETUP
Operating system not found
Parity Check 1
Parity Check 2
Press <F1> to resume, <F2> to Setup
Real time clock error
Shadow RAM Failed at offset: nnnn
System battery is dead - Replace and
run SETUP
System cache error - Cache disabled
System CMOS checksum bad - run
SETUP
System RAM Failed at offset: nnnn
System timer error
nnnn = hexadecimal number
6/14
FT1200 HANDBOOK
Explanation
A fixed disk is not working or not configured properly. Check
to see if the fixed disk is installed properly. Run Setup to be
sure the fixed-disk type is correctly identified.
Type of diskette drive for drive A not correctly identified in
Setup.
Problem with NVRAM (CMOS) access.
The keyboard controller failed test. Try replacing the keyboard.
Keyboard not working.
BIOS discovered a stuck key and displays the scan code nn for
the stuck key.
Unlock the system to proceed.
Monitor type not correctly identified in Setup.
Operating system cannot be located on either drive A or drive
C. Enter Setup and see if fixed disk and drive A are properly
identified.
Parity error found in the system bus. BIOS attempts to locate
the address and display it on the screen. If it cannot locate the
address, it displays ????.
Parity error found in the I/O bus. BIOS attempts to locate the
address and display it on the screen. If it cannot locate the
address, it displays ????.
Displayed after any recoverable error message. Press <F1> to
start the boot process or <F2> to enter Setup and change any
settings.
Real-time clock failed the BIOS test. May require motherboard
repair.
Shadow RAM failed at offset nnnn of the 64 KB block at which
the error was detected.
The CMOS clock battery indicator shows the battery is dead.
Replace the battery and run Setup to reconfigure the system.
RAM cache failed the BIOS test. BIOS disabled the cache.
System CMOS RAM has been corrupted or modified
incorrectly, perhaps by an application program that changes
data stored in CMOS. Run Setup and reconfigure the system
either by getting the default values and/or making your own
selections.
System RAM failed at offset nnnn of the 64 KB block at which
the error was detected.
The timer test failed. Requires repair of system motherboard.