Turn the printer power off.
Wait a full 60 seconds for the motors, valves, etc. to completely reset.
Turn the printer power back on.
If after checking these items the problem persists, contact your Service Provider.

7.10.2 Binder Cartridge is Full But 3DPrint Indicates Empty

Explanation: This is usually caused by a damaged binder cartridge, or a failure in the binder cartridge
pocket.
Solution:
Remove and reseat the binder cartridge. Check the following:
Be sure it's the correct cartridge for that pocket.
Check the label to be sure it's oriented correctly.
Snap it fully into place in the pocket.
If that doesn't solve the problem, try a new binder cartridge.
If a new binder cartridge doesn't solve the problem, contact your Service Provider.