Excessive Unit Dusting - Kärcher KMR 1250 B Service Manual

Hide thumbs Also See for KMR 1250 B:
Table of Contents

Advertisement

KMR 1250 B, LPG, D

Excessive Unit Dusting

3
2
2
1
Lifting filter box
Replacing dust filter
2
1
Installing rubber sleeve
5 / 6
4
3
Troubleshooting Information
Replace dust filter
A noticeable deposit of dust at the impeller fan
exhaust indicates a poorly installed or defective
dust filter.
Raise debris container (1) to half of its travel,
and secure against dropping.
Unsnap clip fasteners (2) on filter enclosure.
Swing filter enclosure (3) forward, then lift
off.
Unfold hand grip (4), pull out, and unlock by
means of a 90-degree turn.
Remove old dust filter (5).
Insert new dust filter (6).
Return hand grip (4) to original position, and
snap into place.
Install filter enclosure (3), and lock clip fas-
teners (2).
Check rubber sleeve
To prevent filter replacement problems caused
by premature corrosion of the locator pin (7) in
the filter receptacle, a rubber sleeve (9) was in-
stalled on units with S/N 10518 and up.
Defective or missing rubber sleeve (9) should be
replaced or retrofitted (refer to service bulletin
no. 1998-045).
1
Debris container
2
Filter enclosure clip fasteners
3
Filter enclosure
4
Hand grip
5/6 Replace dust filter
7
Locator pin
8
Compression spring
9
Rubber sleeve