Maintenance Procedures (Lpg Engine) - Kärcher KMR 1250 B Service Manual

Hide thumbs Also See for KMR 1250 B:
Table of Contents

Advertisement

Troubleshooting Information

Maintenance Procedures (LPG engine)

1
Removing muffler guard
2
Measuring CO value inside muffler tailpipe
Setting CO value w/ mixture control screw (idle
speed)
28
Set CO value (LPG engine)
To adjust CO value, the following measuring de-
vices will be needed:
Tachometer, P/N 6.491-361
Exhaust analyser. Procure suitable CO an-
alyser locally; requires measuring range up
to 2% CO.
1. Set CO value at idle speed
Start engine, and set accelerator lever on
instrument panel to MIN position. Idle speed
should be between 1250 and 1550 RPM (see
also "technical specifications").
Let engine warm up for a few minutes.
Using a floor jack, raise front of unit, and
remove muffler guard (1). There is no other
way to access the muffler outlet.
Measure CO value inside muffler tailpipe (2).
Using the mixture control screw idle speed)
(5), set CO value on gas regulator (4) (nom-
inal CO value is 0.5%).
With the correct adjustment, engine must run
smoothly and quietly, and provide reliable
starting.
With adjustment completed, fix mixture con-
trol screw (5) by applying sealing lacquer.
3
1
Muffler guard
2
Muffler
3
Solenoid valve
4
4
Gas regulator
5
Mixture control screw (idle speed)
5
KMR 1250 LPG

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kmr 1250Kmr 1250 dKmr 1250 lpg