Maintenance Procedures (Lpg Engine) - Kärcher KMR 1250 B Service Manual

Hide thumbs Also See for KMR 1250 B:
Table of Contents

Advertisement

KMR 1250 LPG

Maintenance Procedures (LPG engine)

Adjusting operating speed
Setting CO value w/ mixture stop screw (oper.
speed)
3
Solenoid valve
4
Gas regulator
5
Mixture control screw (idle speed)
6
Carburetor stop screw
7
Mixture control screw (operating speed)
2. Set CO value at operating speed
Set accelerator lever on instrument panel to
MAX position (operating speed).
Measure operating RPM and adjust via stop
screw (6) on carburetor as required. Operat-
ing speed has to be between 2600 and 2700
RPM (see also "technical specifications").
With adjustment completed, fix carburetor
stop screw (6) by applying sealing lacquer.
Check CO value inside muffler tailpipe.
6
Using the mixture control screw (idle speed)
(7) (operating speed), set CO value on gas
7
regulator (4) (nominal CO value is 0.5%).
With the correct adjustment, engine must run
smoothly and quietly, and provide reliable
3
starting.
With adjustment completed, fix mixture con-
trol screw (7) by applying sealing lacquer.
4
5
Troubleshooting Information
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kmr 1250Kmr 1250 dKmr 1250 lpg

Table of Contents