Debris Container – No Full Ascent
Hydraulic unit w/ pressure relief valve
Adjusting pressure relief valve
Adjusting pressure relief valve
1
2
3
4
5
Troubleshooting Information
Adjust pressure relief valve
Raise empty or full debris container to maximum
attainable height (two-hand operation). In this
position hold on the two buttons and measure
the current draw of the hydraulic unit (see "tech-
nical specification"). The current draw provides
a measure of the opening pressure set on the
pressure relief valve.
Hydraulic unit,
adjust pressure relief valve
Remove hydraulic unit but do not discon-
nect hydraulic hoses.
Holding valve insert (3) with wrench, unscrew
cap of pressure relief valve (1). The cap
conceals the valve adjusting screw.
Continue to hold valve insert (3) with wrench,
loosen lock nut (2) on valve adjusting screw.
Using a flat screwdriver, turn adjusting screw:
One-half CW turn increases current draw by
roughly 4 to 5 A (approx. 10 bar, approx. 145
psi).
Finish by tightening lock nut on adjusting
screw, again installing screw cap (1).
Install hydraulic unit: Perform function test,
and measure current draw.
Hydraulic unit,
adjust pressure relief valve
Remove hydraulic unit but do not discon-
nect hydraulic hoses.
Remove screw cap (4). Cap conceals ad-
justing screw (5).
Using a stubby screwdriver, turn adjusting
screw:
One-half CW turn increases current draw by
roughly 4 to 5 A (approx. 10 bar, approx. 145
psi).
Finish by installing screw cap (4).
Install hydraulic unit: Perform function test,
and measure current draw.
1
Cap
2
Lock nut
3
Valve insert
4
Screw cap
5
Adjusting screw