12

Troubleshooting

The following check list is to assist you in locating and rectifying certain fault conditions. If the
problem persists after you have made the checks, contact your local INVACARE supplier/dealer.
12.1
Power chair will not drive, ON/OFF light does not come on, when
ON/OFF switch is pressed.
1. power cable from battery boxes not properly connected to power Module. Check and make
proper connection.
2. Batteries completely flat. Charge batteries. If they do not accept charge, contact your local
INVACARE dealer.
3. Defective power supply cable or connector, contact your local INVACARE dealer.
12.2

Power chair pulls to one side.

1. Check that both motor/gearbox units are fully engaged (clutch levers in normal operating posi-
tion).
2. Check that BOTH front wheels (castors) turn and swivel freely.