Invacare XTERRA GT User Manual page 64

Power chair
Hide thumbs Also See for XTERRA GT:
Table of Contents

Advertisement

2. Connect battery cable(s) to battery(ies) terminal(s)/post(s) as follows (depending on battery
type):
Negative (-) BLACK battery cable to NEGATIVE (-) battery terminal/post.
Positive (+) RED battery cable to POSITIVE (+) battery terminal/post.
3. Secure the battery cable(s)/ring terminal(s) to the battery terminal(s)/post(s), BLACK to NEGA-
TIVE (-) and RED to POSITIVE (+), with the provided 1/4-20 x 7/8-inch hex flange screw and hex
flange locknut. Securely tighten. (depending on battery type).
4. Verify all battery cable(s)/ring terminal(s) are correctly installed and securely tightened.
5. Slide terminal cap(s) down battery cable(s) and onto battery clamps.
6. Secure each terminal cap in place with a tie-wrap (Use tie-wraps 11-1/2-inches long).
NOTE:
It will be necessary to trim excess tie-wrap in order to install the battery box top(s).
7. Install the battery with lid into the wheelchair. Refer to INSTALLING/REMOVING BATTERIES in
this procedure.
NOTE:
New Battery(ies) MUST be fully charged BEFORE using, otherwise the life of the battery(ies) will
be reduced.
8. If necessary, charge the battery(ies). Refer to CHARGING BATTERIES in this procedure.
64