Serial Port Settings
2-10
The default settings are shown in bold italic text.
Parameter
Baud Rate
Parity
Word Length
Selection
Protocol
Device Address
Media Type
To configure the printer serial port
1. Use the DIP Switch Settings table (previous page) and the Serial Port
Settings table (above) to determine which parameters you need to change
and the correct DIP switch settings.
2. Use a small straight-slot screwdriver to set the appropriate DIP switches on
or off.
For example, if you want to change the media type to thermal transfer, set
DIP switch 8 on the bottom bank of switches to the on position.
3. Turn the printer power off and then on for the configuration changes to
take effect.
Settings
1200, 2400, 4800, 9600, 19200
Even, Odd, None
7 bit word, 8 bit word
Intermec, XON/XOFF no status response, XON/XOFF with
status response
A to Z, 0 to 5
Direct thermal, thermal transfer