8.7.3 Timer-cut-out (Fig.13)
turn on again and remain on until the following pro-
least 3-4 seconds it will switch off and remain off until
pressed again.
9. ADJUSTMENT AND SETTING OF THE
DOSE
9.1. Models DE
It is possible to adjust the dose of coffee and hot water
function is enabled)

9.1.1. Adjusting the dose

be adjusted using the button panel or the hot water
controls.
1 Press the button E
from the dispensing unit and the led of the conti-
der to reach the correct coffee amount adjustment
in the cup.
unit and the cup under the spout.
4 Operate the selected button (i.e. button A for one
small cup).
5 One the required coffee amount in the cup has
been reached, press the stop button A. Coffe will
stop pouring and the microprocessor will store the
dose.
6 Press the continuous button E
7 Make the coffee and check the cup amount in order
to check that programming is correct.
If some doses have to be changed (A-B-C-D), once
at point 5 repeat the instructions in points 3-4-5 for
all changed doses.
If all units are to be programmed with the same doses,
of another unit is to be changed (1-2-3-4 doses), pro-
ceed as indicated in the above-mentioned point 1-7,
58
9.1.2. Adjusting the quantity of hot water
-
Proceed as follows:
1 Press the continuous E
and hold down for 8-10 seconds until water stops
variations.
2 Put a cup or a jug to receive the water under the
water spout 15 (Fig.3).
4 Once the required amount is reached, press the
button 5b again. Water will stop pouring and the
microprocessor will store the dose.
5 Once adjusted, press the stop-continuous button
E
6 Pour out doses of hot water to check that program-
ming is correct.
WARNING!
The amount of hot water dispensed can be controlled
press the hot water control button 5B and hold
-
trol button 5B again when the required amount has
been dispensed.
To stop dispensing the measured amounts of hot
water, press the water control button 5B.
9.2. Tray case assembly (Optional) (Fig.14)
The machine is provided with two lateral housing to
does not allow, during installation, to install the ma-
chine in standard version.
To replace the cases installed on the machine, loo-
sen the 3 screws (Fig.21), take off and remove the
right case and replace with the one having smaller
dimensions.

9.3. List of failures

E00
CPU diagnosis
E01
Water lacking
E02
Pressure lacking
E03
Boiler temperature sensor in short circuit
E04
Boiler temperature sensor cut off
E05
Level board lacking
E06
IDS connection lacking
-
-