Warning/Error Messages - Sony F65 Operation Manual

Digital motion picture camera
Hide thumbs Also See for F65:
Table of Contents

Advertisement

Warning/Error Messages

If the battery voltage drops or an error is detected when
power is applied or during operation, the corresponding
indicator lights up/flashes and a message appears on the
subdisplay. The error details are displayed in the self
diagnostics field in settings page 3 on the subdisplay. Also,
a "Warning" message is displayed in the viewfinder.
Indicator
Subdisplay
REC: Flashing red
12 V power supply
voltage indicator
flashing
REC: Flashing red
12 V power supply
rapidly
voltage indicator
flashing rapidly
REC: Flashing red
24 V power supply
voltage indicator
flashing
REC: Flashing red
24 V power supply
rapidly
voltage indicator
flashing rapidly
REC: Flashing when
synced with SR-R4.
REC: Flashing when
synced with SR-R4.
DIAGNOSIS:
Displays same
Flashing red rapidly
message as self
diagnostics field in a
dialog.
DIAGNOSIS:
Flashing red rapidly
DIAGNOSIS:
Flashing red rapidly
DIAGNOSIS:
Flashing red
DIAGNOSIS: Lit red
DOCK: Lit yellow
DIAGNOSIS: Lit red
DOCK: Lit red
DIAGNOSIS: Lit red
DOCK: Not lit
DIAGNOSIS: Lit red
Self diagnostics
field indication
12V Battery (Near
End)
12V Battery (End)
24V Battery (Near
End)
24V Battery (End)
Media Remain (Near
End)
Media Remain (End)
Temperature NG!
Shutdown Camera
Fan1 NG!
Fan2 NG!
Sync Error
Optical Level Care
Optical Level NG
Optical Level No Input No signal is input on the Recorder connector.
CRCC Error occurred A Cyclic Redundancy Check Code (CRCC) error
Meaning
The voltage of the 12 V power supply has fallen to the
Near End value setting.
The voltage of the 12 V power supply has fallen to the
End value setting.
The voltage of the 24 V power supply has fallen to the
Near End value setting.
The voltage of the 24 V power supply has fallen to the
End value setting.
The remaining media on the SR-R4 has reduced to the
Near End value setting.
The remaining media on the SR-R4 has reduced to the
End value setting.
The internal camera temperature has reached its limit.
Turn off the camera power supply.
Consult your local Sony representative.
Fan 1 near the top panel stopped.
Consult your local Sony representative.
Fan 2 near the top panel stopped.
Consult your local Sony representative.
A sync error occurred.
If the error continues, consult your local Sony
representative.
The optical level of the Recorder connector has reduced
to caution level.
Clean the Recorder connector or replace the optical
module.
A light reception error occurred with the Recorder
connector.
Immediately, clean the Recorder connector or replace
the optical module.
occurred with the Recorder connector.
If the error continues, consult your local Sony
representative.
47
Warning/Error Messages

Advertisement

Table of Contents
loading

Table of Contents