Warning/Error Messages - Sony F23 Operation Manual

Digital cinematography camera
Hide thumbs Also See for F23:
Table of Contents

Advertisement

Warning/Error Messages

If battery power is low or a problem occurs at power on or
during operation, a warning is given by an indicator
flashing or various alarm indications.
Viewfinder screen
Basic status
Message
display (page 39)
BATT 12 V flashing
BATT 12 V quick
flashing
BATT 24 V flashing
BATT 24 V quick
flashing
TEMPERATURE CARE
TEMPERATURE
WARNING
SHUTDOWN CAMERA
OHB/SIDE FAN NG!
PS FAN NG!
CAM?
OHB NG!
CAM?
AD BOARD NG!
CAM?
DPR BOARD NG!
CAM?
VDA BOARD NG!
CAM?
TR BOARD NG!
CAM?
AT BOARD NG!
I/F BOX NG!
UNKNOWN RECORDER
VTR ALARM
VTR WARNING
Subdisplay
RUN
indicator
BATT 12 V flashing Flashing
BATT 12 V quick
Quick
flashing
flashing
BATT 24 V flashing Flashing
BATT 24 V quick
Quick
flashing
flashing
Quick
flashing
Quick
flashing
Meaning
Voltage of the 12 V power becomes low,
reaching the specified NEAR END value.
Voltage of the 12 V power becomes too
low, reaching the specified END value.
Voltage of the 24 V power becomes low,
reaching the specified NEAR END value.
Voltage of the 24 V power becomes too
low, reaching the specified END value.
Temperature inside the camera raises.
Temperature inside the camera raises to
the limit.
The camera must be turned off for safety.
The fan near the CCD or the fan near the
side panel stops.
The fan near the power unit stops.
Abnormality of the CCD unit
Abnormality of the AD board
Abnormality of the DPR board
Abnormality of the VDA board
Abnormality of the TR board
Abnormality of the AT board
An unknown interface box is connected.
An unknown recorder is connected.
Alarm occurs at the SRW-1.
Warning occurs at the SRW-1.
Using the MSU-900/950