Warning/Error Messages

If the battery voltage drops or an error is detected when
power is applied or during operation, the corresponding
indicator lights up/flashes and a message appears on the
subdisplay. The error details are displayed in the self-
diagnostics on settings page 3 on the subdisplay and in the
viewfinder.
Warnings and error messages occurring on the SR-R4 are
also displayed in the self-diagnostics field.
Indicator
REC: Flashing red
REC: Flashing red
rapidly
REC: Flashing red
REC: Flashing red
rapidly
REC: Flashing when
synced with SR-R4.
REC: Flashing when
synced with SR-R4.
DIAGNOSIS:
Flashing red rapidly
DIAGNOSIS:
Flashing red rapidly
DIAGNOSIS:
Flashing red rapidly
DIAGNOSIS:
Flashing red
DIAGNOSIS: Lit red
DOCK: Lit yellow
DIAGNOSIS: Lit red
DOCK: Lit red
DIAGNOSIS: Lit red
DOCK: Not lit
DIAGNOSIS: Lit red
58
Warning/Error Messages
Subdisplay
Self diagnostics
field indication
12 V power supply
12V Battery (Near
voltage indicator
End)
flashing
12 V power supply
12V Battery (End)
voltage indicator
flashing rapidly
24 V power supply
24V Battery (Near
voltage indicator
End)
flashing
24 V power supply
24V Battery (End)
voltage indicator
flashing rapidly
Media remaining
Media Remain (Near
indicator flashing
End)
Media remaining
Media Remain (End)
indicator flashing
rapidly
Displays same
Temperature NG!
message as self
Shutdown Camera
diagnostics field in a
dialog.
Fan1 NG!
Fan1 NG!
Fan2 NG!
Fan2 NG!
Sync Error
Sync Error
Optical Level Care
Optical Level Care
Optical Level NG
Optical Level NG
Optical Level No Input Optical Level No Input No signal is input on the Recorder connector.
CRCC Error occurred CRCC Error occurred A Cyclic Redundancy Check Code (CRCC) error
For details about SR-R4 messages, refer to the operation
manual of the SR-R4.
A message prompt is also displayed in the viewfinder/
monitor to execute the APR function if a defect is detected
in the image sensor when the camera powers on or if the
APR function is not executed regularly. If prompted,
execute Automatic Pixel Noise Reduction on the
<Maintenance> page of the Diagnosis menu.
Meaning
The voltage of the 12 V power supply has fallen to the
Near End value setting.
The voltage of the 12 V power supply has fallen to the
End value setting.
The voltage of the 24 V power supply has fallen to the
Near End value setting.
The voltage of the 24 V power supply has fallen to the
End value setting.
The remaining media on the SR-R4 has reduced to the
Near End value setting.
The remaining media on the SR-R4 has reduced to the
End value setting.
The internal camera temperature has reached its limit.
Turn off the camera power supply.
Consult your local Sony representative.
Fan 1 near the top panel stopped.
Consult your local Sony representative.
Fan 2 near the top panel stopped.
Consult your local Sony representative.
A sync error occurred.
If the error continues, consult your local Sony
representative.
The optical level of the Recorder connector has reduced
to caution level.
Clean the Recorder connector or replace the optical
module.
A light reception error occurred with the Recorder
connector.
Immediately, clean the Recorder connector or replace
the optical module.
occurred with the Recorder connector. Clean the
recorder connector.
If the error continues, even after cleaning, consult your
local Sony representative.