The second parameter indicates the scene which was selected. If off button is pushed, it is indicated by a zero. A Master Raise is indicated by an 18, and a
Master Lower is indicated by a 19.
Example of response: D3<CR><LF>
The scene 3 button was pushed on the PAV control unit addressed A4.
Two-Button Control (NTGRX-2B-SL) The first parameter indicates the address as above. The second parameter is a 1 to indicated that the Raise or top
button has been pushed as is a 0 to indicate that a Lower or bottom button has been pushed.
A/V Interface Control configured as a Special Function Control (Interface configured as 4Q) Unlike the other controls, first parameter will be a
capital letter if any of the control's four functions, Sequence, Zone Lock, Scene Lock or Fad Override are active. A lower case letter indicates that no functions
are active. The second parameter will be a character that contains encoded information about which functions are active. For details on the format of this
response, contact Lutron.
Master Control (NTGRX-4M)
Partition Control (NTGRX-4PS) This status of these Wallstations cannot be the Programming Interface. When buttons are pushed on the Master Control and
Partition Control, 1s and 0s may be returned by the RS232 interface.
DIP Switch 7: Scene Status – In the ON position, the Programming interface will return the current scene of all eight selected. The response will be a 'ss',
followed by a string of eight ASCII characters, one for each PAV control unit. Each character represents the scene of each PAV control unit indicated by an 'A',
scene 11 will be indicated by a 'B', and so on up to scene 16. A '0' will be returned if the PAV control unit is turned off, and 'M' will be returned if the PAV
control unit is missing or not responding. An 'R' will be returned if a Master Raise is being sent, and a 'L' will be returned if a control unit is sending a Master
Lower. Regardless if this switch is in the ON or OFF position, the current scene can be obtained by using the REQUEST SCENE STATUS command. See the
GRX-RS232 Protocol and Command Set included with the PAV-6M unit for details.
Example of response: ssM180R2D2<CR><LF>
Control Unit A1 is missing
Control Unit A2 is in scene 1
Control Unit A3 is in scene 8
Control Unit A4 is off
Control Unit A5 is sending a Master Raise
Control Unit A6 is in scene 2
Control Unit A7 is in scene 13
Control Unit A8 is in scene 2
DIP Switch 8: Timeclock ON/OFF– In the ON position, the internal timeclock of the PAV can control the
operation of the control unit. Timeclock schedules and the Super Sequence are configured and programmed
using Lutron's Liaison software.
Addressed as:
A1
A2
A3
A4
A5
A6
A7
A8
Addressed as:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Page 9
Indicated by:
A or a
B or b
C or c
D or d
E or e
F or f
G or g
H or h
Indicated by:
I or i
J or j
K or k
L or l
M or m
N or n
O or o
P or p
Q or q
R or r
S or s
T or t
U or u
V or v
W or w
X or x

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pav6s-120Pav6s-230Pav6m-230

Table of Contents