User Manuals: Lutron Electronics PALLADIOM Controls
Manuals and User Guides for Lutron Electronics PALLADIOM Controls. We have
1
Lutron Electronics PALLADIOM Controls manual available for free PDF download: Configuration Manual
Lutron Electronics PALLADIOM Configuration Manual (41 pages)
Brand:
Lutron Electronics
| Category:
Thermostat
| Size: 4 MB
Table of Contents
Table of Contents
2
Description
4
Step 1: Identify the HVAC Equipment and Confirm Device Installation
5
Identify the HVAC Equipment
5
Confirm Device Installation
5
Programming Menu Overview
7
Step 2: Equipment Configuration Mode
7
Step 3: Select the HVAC Controller
8
Step 4: Set the SMC55-HWQS Basic Parameters for System Compatibility
9
(01B): System Type
11
(02B): Heat Stages
11
(03B): Run Auxiliary Heat
12
With Other Heat Stages
12
(04B): Auxiliary Heat (Aux/W ) Upstage Delay
12
(05B): Cool Stages
13
(06B): Heat Fan Control
13
(07B): Changeover/Reversing Valve (O/B) Type
13
(08B): Valve / Element Type
14
(09B): Fan Type
14
(10B): 2-Pipe Mode
15
(11B): Underfloor Heating Control
16
Saving and Exiting Basic Configuration
17
Step 5: Set the SMC55-HWQS Advanced Parameters to Modify the Functionality of the HVAC System
18
Parameters Applicable to All Types of HVAC Equipment
22
(01A) Function Type
22
(02A) Temperature Sensor Type
22
(06A) Minimum Fan on Time
22
(07A) Extended Cool Fan Time (OCFT)
22
(08A) Extended Heat Fan Time (OHFT)
22
(11A) Cool Fan on Delay (CFOD)
22
(12A) Heat Fan on Delay (HFOD)
22
(18A) Standalone Temperature Operation Mode
22
(19A) Standalone Temperature Fan Mode
22
(30A) Cannot Reach Setpoint Timeout
23
(31A) Cannot Reach Setpoint Action
23
Parameters Applicable to Conventional and Heat Pump Systems
23
(70A) Minimum Compressor Run Time (MCRT)
23
(71A) Minimum Compressor off Time (MCOT)
23
(74A) Heat Stage 1-On Delta
24
(75A) Heat Stage 1-Off Delta
24
(76A) Heat Stage 2 (y /Aux)-On Delta
24
(77A) Heat Stage 2-Off Delta
24
(78A) Heat Stage 3 (Aux)-On Delta
24
(79A) Heat Stage 3 (Aux)-Off Delta
24
(80A) Cool Stage 1-On Delta
24
(81A) Cool Stage 1-Off Delta
24
(82A) Cool Stage 2-On Delta
24
(83A) Cool Stage 2-Off Delta
25
(84A) Compressor Cool Stage 2 Upstage Delay (CC2SUD)
25
(85A) Compressor Heat Stage 2 Upstage Delay (CH2SUD)
25
(88A) Reversing Valve Delay (RVD)
25
Advertisement
Advertisement
Related Products
Lutron Electronics PAV6M-120
Lutron Electronics PAV6S-120
Lutron Electronics PAV6S-230
Lutron Electronics PAV6M-230
Lutron Electronics PM-9107
Lutron Electronics PH-220S
Lutron Electronics PowPak FCJ-ECO
Lutron Electronics PCE-228
Lutron Electronics Caseta Pico PD-6WCL
Lutron Electronics Caseta PD-5ANS
Lutron Electronics Categories
Measuring Instruments
Switch
Control Unit
Dimmer
Controller
More Lutron Electronics Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL