FLIR Tau CNV User Manual page 47

Night vision camera
Table of Contents

Advertisement

Analog Video Gain – Enables or disables the main 16 bit to 8 bit analog remapping algorithm to
adjust the analog image.
Day/Night Filter – Moves the motorized day/night filter slider if your camera is so equipped.
Color Balance – Allows the user to select automatic color balance or to perform a manual color
balance.
Test Pattern – Displays the test pattern.
The "Configuration" window is completely new in the advanced mode and offers the following functions:
Flat Field Correction – Allows the user to perform a Non-Uniformity Correction (NUC) in the
field if conditions require it. Note that this NUC will only be valid while the camera is powered
on and will reset to default when the camera is power cycled.
Camera Link (Digital) Output – The user can select whether the output of the digital data is 14
or 16 bits and also whether the image processing is performed prior to data output.
Trigger Type – As previously mentioned, the camera can operate in two different trigger modes:
o Internal – The camera operates at up to 30FPS on an internally generated free running
clock.
o External – The camera is synced to a signal on the external trigger input.
Trigger Source – This option becomes available when an external trigger is selected. It chooses
which external trigger the camera will be using.
Number of Lines (Camera Link Only) – The user can select whether the output is 1280x960 or
1280x720. Note that this only affects the digital output.
10-10032-01
Rev A1
2011 FLIR Advanced Imaging Systems
Tau CNV Camera User's Manual
ECO: 594