Track 1 Settings Part 2
X040 ll ss
ll
restrict track 1 reading to cards with a length of ll. Set to 00 for any length.
ss
seperator character translation. If this parameter is set to a non 00 value, then any seperator characters in the
magstripe will be converted to this value. This parameter is a 2-digit (max 99) decimal equivalent of any ascii
character ( 49 = 0, 65 = A).
Track 1 Prefix
X055 aaa bbb ccc ddd eee
aaa-eee 3-digit ascii value for a character, max=126, 000=end
You can program up to 5 characters to be prepended to ind2of5 data. To set a character use the 3-digit decimal value for the
character, i.e. "A" = hex 41 = 065 decimal. Use 000 to signify the end of the prefix data.
Example:
X055049050000000000
Inserts a prefix of "12" in front of the track 1 data.
Track 1 Suffix
X058 aaa bbb ccc ddd eee
aaa-eee 3-digit ascii value for a character, max=126, 000=end
You can program up to 5 characters to be prepended to ind2of5 data. To set a character use the 3-digit decimal value for the
character, i.e. "A" = hex 41 = 065 decimal. Use 000 to signify the end of the suffix data.
Example:
X058065066000000000