For tank anchoring to the vehicle, special
threaded inserts (Fig.18 Ref. 5 ) and (Fig.16 Ref.
7) should be used according to requirements.

4.10 Fuel reserve

Both fuel tank models are provided with a tap
with fuel warning (Fig.18 Ref.3). To electrically
connect
this
component,
screwed on the tap body then connect the other
tap wire to the special three-pole connector
Faston terminal via an electric lead (Fig.13 Ref.
8); to identify the correct Faston terminal, check
the wiring diagram.
The fuel reserve available in both tanks is
approximately 4 litres.
A special fuel warning light (Fig.30 Ref.8) will
light up to show that the fuel level inside the tank
has gone below the safe reserve level.

4.11 Battery charger

ENERGY 4010B generating sets are equipped
with a battery charger which can deliver current
of approximately 10 Amp at 12 V. It can be used
to recharge the generating set start-up battery.
To obtain this function, use a 2,5 mm
section cable to connect the terminal identified by
CHARG (Fig.19 Ref. 1) to the positive pole (red
cable) of the generating set (Fig. 19 Ref. 2)
possible to use the 12 Volt alternating current
output provided on the bipolar connector shown
in Fig. 13 Ref. 6 .

4.11.1 Auxiliary Battery Charger

If you wish to recharge a different battery or do
not wish to use the CHARG terminal, it is To
these two Faston terminals,
section cables should be connected to obtain
interfacing to an optional RCB regulator (code
05424) as shown in Fig. 20.
14
GB
ground
the
wire
2
cross-
4 sq.mm cross-
Energy 4010 B
The generating set will not
autonomously recharge the battery used for
starting-up unless this is connected to a
battery charger.
Vers. 001